Improvement in electrical energy efficiency of solar photovoltaic panel by passive refrigeration cooling system

M. Chandrasekar,S. Rajkumar,M. Varatharajulu
DOI: https://doi.org/10.1007/s42108-021-00175-9
2022-03-21
International Journal of Energy and Water Resources
Abstract:A novel passive refrigeration technique for cooling solar photovoltaic (PV) panel using the Capillary pumped loop (CPL) system to improve PV electrical conversion efficiency is proposed in this work. Refrigerants R134a (Tetra fluro ethane) and R22 (Chloro di fluoro methane) were used as coolants in the CPL system. Experimental results revealed that there was a drop in PV panel temperature by 2 °C with R134a refrigerant and 3 °C with R22 refrigerant compared to the uncooled panel. Due to this panel temperature drop, the PV electrical power was increased by 7.33% for R134a refrigerant and by 10.54% for R22 refrigerant compared to the uncooled panel. Thus, the electrical conversion efficiency was improved by 0.74% and 1.04% for R134a and R22 refrigerants, respectively, compared to the uncooled panel. The prediction correlation for the power, fill factor (FF), and efficiency was obtained using the principle of analysis of variance (ANOVA) with the statistical package Design Expert 7.0.0 and was justified by experimental results with a percentage deviation of less than ± 5%.
What problem does this paper attempt to address?