High-speed three-dimensional photoacoustic computed tomography for preclinical research and clinical translation

Li Lin,Peng Hu,Xin Tong,Shuai Na,Rui Cao,Xiaoyun Yuan,David C. Garrett,Junhui Shi,Konstantin Maslov,Lihong V. Wang
DOI: https://doi.org/10.1038/s41467-021-21232-1
IF: 16.6
2021-02-09
Nature Communications
Abstract:Abstract Photoacoustic computed tomography (PACT) has generated increasing interest for uses in preclinical research and clinical translation. However, the imaging depth, speed, and quality of existing PACT systems have previously limited the potential applications of this technology. To overcome these issues, we developed a three-dimensional photoacoustic computed tomography (3D-PACT) system that features large imaging depth, scalable field of view with isotropic spatial resolution, high imaging speed, and superior image quality. 3D-PACT allows for multipurpose imaging to reveal detailed angiographic information in biological tissues ranging from the rodent brain to the human breast. In the rat brain, we visualize whole brain vasculatures and hemodynamics. In the human breast, an in vivo imaging depth of 4 cm is achieved by scanning the breast within a single breath hold of 10 s. Here, we introduce the 3D-PACT system to provide a unique tool for preclinical research and an appealing prototype for clinical translation.
multidisciplinary sciences
What problem does this paper attempt to address?
The problems that this paper attempts to solve are the limitations of existing photoacoustic computed tomography (PACT) systems in imaging depth, speed, and quality, which limit the application potential of this technology. Specifically: 1. **Insufficient imaging depth**: Existing PACT systems cannot achieve sufficient imaging depth, especially having difficulties in imaging deep - layer structures inside biological tissues. 2. **Slow imaging speed**: The imaging speed of existing systems is slow, which restricts their application in dynamic processes, such as functional imaging. 3. **Poor image quality**: Due to the limited field - of - view angle (< 2π steradian), the image quality is not high, especially in terms of high resolution and contrast. To solve these problems, the authors developed a three - dimensional photoacoustic computed tomography system (3D - PACT), which has the following features: - **Large imaging depth**: It can provide a deeper imaging depth and is suitable for imaging at different scales from rodent brains to human breasts. - **Scalable field - of - view**: It has a scalable field - of - view range and has isotropic high spatial resolution in three - dimensional space. - **High imaging speed**: It significantly improves the imaging speed, can complete high - quality image reconstruction in a short time, reduces motion artifacts and supports functional studies. - **Superior image quality**: By optimizing the hardware design and signal - processing algorithms, a higher contrast - to - noise ratio (CNR) is achieved, thus providing clearer images. Through these improvements, the 3D - PACT system can provide a multi - functional imaging tool in pre - clinical research and clinical translation, and is especially suitable for revealing detailed vascular structures and hemodynamic information in biological tissues. For example, in the rat brain, the entire cerebrovascular network and blood flow dynamics can be visualized; in the human breast, an in - vivo imaging depth of 4 centimeters can be achieved within one breath - hold (10 seconds). In summary, this paper aims to overcome the limitations of existing PACT technology by developing the 3D - PACT system, thereby providing a more powerful and flexible imaging solution for biomedical research and clinical applications.