Corrections to “Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging: In Vitro and In Vivo Evaluation”

Verya Daeichin,Tom van Rooij,Ilya Skachkov,Bulent Ergin,Patricia A. C. Specht,Alexandre Lima,Can Ince,Johan G. Bosch,Antonius F. W. van der Steen,Nico de Jong,Klazina Kooiman
DOI: https://doi.org/10.1109/tuffc.2021.3067599
2021-06-01
Abstract:In the above article [1], the authors regret that there was a mistake in calculating the mol% of the microbubble coating composition used. For all experiments, the unit in mg/mL was utilized and the conversion mistake only came when converting to mol% in order to define the ratio between the coating formulation components. The correct molecular weight of PEG-40 stearate is 2046.54 g/mol [2], [3], not 328.53 g/mol. On page 556, Table I should read as shown here.