Development and Validation of a GC-FID Method for the Quantitation of Δ 8-Tetrahydrocannabinol and Impurities Found in Synthetic Δ 8-Tetrahydrocannabinol and Vaping Products
Waseem Gul,Iram Shahzadi,Nandakumara Sarma,Nam-Cheol Kim,Mahmoud A. ElSohly,ElSohly,Mahmoud A.
DOI: https://doi.org/10.1055/a-2249-7824
IF: 3.007
2024-02-23
Planta Medica
Abstract:Concerns about health hazards associated with the consumption of trans -delta-8-tetrahydrocannabinol products were highlighted in public health advisories from the U. S. Food and Drug Administration and U. S. Centers for Disease Control and Prevention. Simple and rapid quantitative methods to determine trans -delta-8-tetrahydrocannabinol impurities are vital to analyze such products. In this study, a gas chromatography-flame ionization detection method was developed and validated for the determination of delta-8-tetrahydrocannabinol and some of its impurities (recently published) found in synthesized trans -delta-8-tetrahydrocannabinol raw material and included olivetol, cannabicitran, Δ 8 - cis - iso -tetrahydrocannabinol, Δ 4 - iso -tetrahydrocannabinol, iso -tetrahydrocannabifuran, cannabidiol, Δ 4,8 - iso -tetrahydrocannabinol, Δ 8 - iso -tetrahydrocannabinol, 4,8- epoxy - iso -tetrahydrocannabinol, trans - Δ 9 -tetrahydrocannabinol, 8-hydroxy- iso -THC, 9 α -hydroxyhexahydrocannabinol, and 9 β -hydroxyhexahydrocannabinol. Validation of the method was assessed according to the International Council for Harmonization guidelines and confirmed linearity with R 2 ≥ 0.99 for all the target analytes. The limit of detection and limit of quantitation were 1.5 and 5 μg/mL, respectively, except for olivetol, which had a limit of detection of 3 μg/mL and a limit of quantitation of 10 μg/mL. Method precision was calculated as % relative standard deviation and the values were less than 8.4 and 9.9% for the intraday precision and inter-day precision, respectively. The accuracy ranged from 85 to 118%. The method was then applied to the analysis of 21 commercially marketed vaping products claiming to contain delta-8-tetrahydrocannabinol. The products analyzed by this method have various levels of these impurities, with all products far exceeding the 0.3% of trans - Δ 9 -tetrahydrocannabinol limit for hemp under the Agriculture Improvement Act of 2018. The developed gas chromatography-flame ionization detection method can be an important tool for monitoring delta-8-tetrahydrocannabinol impurities in commercial products. Received: 14 September 2023 Accepted after revision: 14 January 2024 Article published online: 22 February 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
pharmacology & pharmacy,chemistry, medicinal,integrative & complementary medicine,plant sciences