Vertical Flow Cellulose-Based Assays for SARS-CoV-2 Antibody Detection in Human Serum

Seunghyeon Kim,Yining Hao,Eric A. Miller,Dousabel M. Y. Tay,Emma Yee,Patthara Kongsuphol,Huan Jia,Megan McBee,Peter R. Preiser,Hadley D. Sikes
DOI: https://doi.org/10.1021/acssensors.1c00235
IF: 8.9
2021-04-06
ACS Sensors
Abstract:Rapid and inexpensive serological tests for severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) antibodies are essential to conduct large-scale seroprevalence surveys and can potentially complement nucleic acid or antigen tests at the point of care. During the COVID-19 pandemic, extreme demand for traditional lateral flow tests has stressed manufacturing capacity and supply chains. Motivated by this limitation, we developed a SARS-CoV-2 antibody test using cellulose, an alternative membrane material, and a double-antigen sandwich format. Functionalized SARS-CoV-2 antigens were used as both capture and reporter binders, replacing the anti-human antibodies currently used in lateral flow tests. The test could provide enhanced sensitivity because it labels only antibodies against SARS-CoV-2 and the signal intensity is not diminished due to other human antibodies in serum. Three-dimensional channels in the assay were designed to have consistent flow rates and be easily manufactured by folding wax-printed paper. We demonstrated that this simple, vertical flow, cellulose-based assay could detect SARS-CoV-2 antibodies in clinical samples within 15 min, and the results were consistent with those from a laboratory, bead-based chemiluminescence immunoassay that was granted emergency use approval by the US FDA.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acssensors.1c00235?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acssensors.1c00235</a>.Methods: protein expression, purification, and characterization; chemical biotinylation of NP and characterization; raw data for calculating flow rates in single-layer and multilayer devices (Table S1); oligonucleotide sequences of primers (Table S2); protein sequences (Table S3); original SDS-PAGE gel images of purified reagent proteins (Figure S1); comparison of SDS-PAGE gel images of NP-CBD and CBD-NP (Figure S2); formation of desired antibody complex (CBD-NP-Ab-NP-biotin) from various concentrations of NP-CBD and NP-biotin (Figure S3); analysis of clinical samples with vertical-flow antigen-down immunoassays and enzyme-linked immunosorbent assays (Figure S4) (<a class="ext-link" href="/doi/suppl/10.1021/acssensors.1c00235/suppl_file/se1c00235_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, multidisciplinary, analytical,nanoscience & nanotechnology
What problem does this paper attempt to address?