A study of slip factor and velocity components at the rotor exit of forward-curved squirrel cage fans, using laser Doppler anemometry

N Montazerin,A Damangir,A. Kazemi Fard
DOI: https://doi.org/10.1243/0957650011538712
2001-06-01
Abstract:Velocity profiles outside the rotor of four squirrel cage fans are measured in order to calculate their local slip factors. They show that the fluid exit angle from the rotor and the blade outlet angle of such fans are very different. Inlet configuration and volute spread angle both affected the direction of the flow out of the rotor and hence the slip factor. The general understanding in centrifugal turbomachines is that more energy transfer per unit mass is equivalent to a larger tangential component of velocity and therefore a larger slip factor. In squirrel cage fans a small slip factor results from a large radial velocity component out of the rotor. This gives a larger volumetric flowrate with no sensible head loss. The advantages of a large incidence angle and a large deviation mean that flow adherence to the blades is not always a prime design criterion in such fans.
engineering, mechanical,thermodynamics
What problem does this paper attempt to address?