Abstract 147: AED on the Fly: A Drone Delivery Feasibility Study for Rural and Remote Out-Of-Hospital Cardiac Arrest

Sheldon Cheskes,Paul Snobelen,Shelley McLeod,Steven Brooks,Christian Vaillancourt,Timothy Chan,Katie N Dainty,Mike Nolan
DOI: https://doi.org/10.1161/circ.140.suppl_2.147
IF: 37.8
2019-11-19
Circulation
Abstract:Introduction: Time-to-treatment plays a pivotal role in survival from sudden cardiac arrest (SCA). Every minute of delay in defibrillation results in a 7-10% reduction in survival. Time to defibrillation is particularly problematic in rural and remote regions, where traditional bystander and EMS response is often prolonged and automated external defibrillators (AED) are often not available. The objective of this study was to examine the feasibility of a novel AED drone delivery method for rural and remote SCA. A secondary objective was to compare times between AED drone delivery and ambulance response to various mock SCA resuscitations. Methods: We conducted four simulations to determine the feasibility of AED drone delivery to mock SCA resuscitations in a rural public setting in Ontario, Canada. During each simulation, a “mock” call was placed to 911 and a single AED drone and an ambulance were simultaneously dispatched from the same location to a pre-determined destination for a mock SCA. Once on scene, trained first responders retrieved the AED from the drone and initiated resuscitative efforts on a manikin until paramedics arrived. Results: The distance from dispatch location to scene varied from 6.6 kms to 8.8 kms. Mean (SD) response time from 911 call to arrive at mock code location was 11.2 (1.0) for EMS compared to 8.1 (0.1) minutes for AED drone delivery. In all four simulations, the AED drone arrived before EMS, ranging from 2.1 minutes to 4.4 minutes faster. Mean (SD) time from AED removal from drone to application to manikin by a trained responder was 35(5) sec. No difficulties were encountered in drone activation by dispatch, drone lift off, landing or removal of the AED from the drone by responders. Conclusions: This implementation study suggests AED drone delivery is feasible with improvements in response time during a simulated SCA scenario. These results suggest the potential for AED drone delivery to decrease time to first defibrillation in rural and remote communities. Further research is required to determine the appropriate distance for drone delivery of an AED in an integrated EMS system as well as optimal strategies to simplify bystander application of a drone delivered AED.
cardiac & cardiovascular systems,peripheral vascular disease
What problem does this paper attempt to address?