Direct measurement of boundary layer thickness on ion-exchange membrane surfaces during reverse electrodialysis
Mei Li,Jiabin Guo,Nianchun Zhang,Hongbo Zheng,Xiaoliang Li,Yanmeng Hao,zheyu xiang
DOI: https://doi.org/10.1039/d3se00404j
IF: 6.813
2023-06-01
Sustainable Energy & Fuels
Abstract:A two-compartment electrolytic cell was constructed to simulate the membrane-solution system in reverse electrodialysis, based on which a potential analysis method was proposed to measure the thickness of the diffusion boundary layer on the membrane surface. By changing the position of the moving electrode in the system and measuring the potential difference between the fixed electrode and the moving electrode, the potential distribution on the membrane surface was obtained. The thickness of the diffusion boundary layer was then determined by analyzing the potential distribution. In addition, the effects of different operating conditions on the thickness of the diffusion boundary layer were evaluated. The results showed that the thickness of the diffusion boundary layer decreased significantly with increasing flow rate and temperature, and concentration polarization was suppressed. And the thickness of the diffusion boundary layer increased with the concentration of high salt solution, but decreased with the concentration of high and low salt solutions. Furthermore, this study found that the effect of membrane type on the thickness of the diffusion boundary layer was relatively weak, based on the use of three commercially available membranes.
materials science, multidisciplinary,chemistry, physical,energy & fuels