Hydrogen Jet Fire from a Thermally Activated Pressure Relief Device (TPRD) from Onboard Storage in a Naturally Ventilated Covered Car Park

Harem Hussein,Síle Brennan,Vladimir Molkov
DOI: https://doi.org/10.3390/hydrogen2030018
2021-08-17
Hydrogen
Abstract:Hydrogen jet fires from a thermally activated pressure relief device (TPRD) on onboard storage are considered for a vehicle in a naturally ventilated covered car park. Computational Fluid Dynamics was used to predict behaviour of ignited releases from a 70 MPa tank into a naturally ventilated covered car park. Releases through TPRD diameters 3.34, 2 and 0.5 mm were studied to understand effect on hazard distances from the vehicle. A vertical release, and downward releases at 0°, 30° and 45° for TPRD diameters 2 and 0.5 mm were considered, accounting for tank blowdown. direction of a downward release was found to significantly contribute to decrease of temperature in a hot cloud under the ceiling. Whilst the ceiling is reached by a jet exceeding 300 °C for a release through a TPRD of 2 mm for inclinations of either 0°, 30° or 45°, an ignited release through a TPRD of 0.5 mm and angle of 45° did not produce a cloud with a temperature above 300 °C at the ceiling during blowdown. The research findings, specifically regarding the extent of the cloud of hot gasses, have implications for the design of mechanical ventilation systems.
What problem does this paper attempt to address?