Ultrasensitive and Simultaneous Detection of Two Specific SARS-CoV-2 Antigens in Human Specimens Using Direct/Enrichment Dual-Mode Fluorescence Lateral Flow Immunoassay

Chongwen Wang,Xiaodan Cheng,Liyan Liu,Xiaochang Zhang,Xingsheng Yang,Shuai Zheng,Zhen Rong,Shengqi Wang
DOI: https://doi.org/10.1021/acsami.1c11461
2021-08-20
Abstract:Sensitive point-of-care methods for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigens in clinical specimens are urgently needed to achieve rapid screening of viral infection. We developed a magnetic quantum dot-based dual-mode lateral flow immunoassay (LFIA) biosensor for the high-sensitivity simultaneous detection of SARS-CoV-2 spike (S) and nucleocapsid protein (NP) antigens, which is beneficial for improving the detection accuracy and efficiency of SARS-CoV-2 infection in the point-of-care testing area. A high-performance magnetic quantum dot with a triple-QD shell (MagTQD) nanotag was first fabricated and integrated into the LFIA system to provide superior fluorescence signals, enrichment ability, and detectability for S/NP antigen testing. Two detection modes were provided by the proposed MagTQD-LFIA. The direct mode was used for rapid screening or urgent detection of suspected samples within 10 min, and the enrichment mode was used for the highly sensitive and quantitative analysis of SARS-CoV-2 antigens in biological samples without the interference of the "hook effect." The simultaneous detection of SARS-CoV-2 S/NP antigens was conducted in one LFIA strip, and the detection limits for two antigens under direct and enrichment modes were 1 and 0.5 pg/mL, respectively. The MagTQD-LFIA showed high accuracy, specificity, and stability in saliva and nasal swab samples and is an efficient tool with flexibility to meet the testing requirements for SARS-CoV-2 antigens in various situations.The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acsami.1c11461.Additional experimental description (S1: materials, reagents, and instrumentation; S2: preparation of AuNP-LFIA; S3: calculation of the maximum number of QDs on the MagTQD; S4: optimization of the Fe3O4 core for MagTQD tags; and S5: optimization of assay conditions for MagTQD-LFIA strip); SEM image of Fe3O4@PEI MNPs; zeta potentials of the products from each step; stability results of MagTQD nanocomposites; optimization of the size of MagTQD NPs; screening of suitable SARS-CoV-2 S and NP antibodies for the LFIA system; SEM images of the test lines for 0.1 ng/mL SARS-CoV-2 S and NP antigens; optimization of the NC membrane, running buffer, and detection antibody concentration on the test lines for the MagTQD-LFIA strip; TEM images of MagQDs; optimization of the testing time for the dual-mode MagTQD-LFIA; recovery results for SARS-CoV-2 S/NP antigens spiked in human saliva and nasal swab samples; reproducibility results of the dual-mode MagTQD-LFIA strips; and optimization of QD layers of magnetic QD tags for the LFIA system (PDF)This article has not yet been cited by other publications.
materials science, multidisciplinary,nanoscience & nanotechnology
What problem does this paper attempt to address?