Stereometric Assessment of TMJ Space Variation by Occlusal Splints

D.A. Ettlin,H. Mang,V. Colombo,S. Palla,L.M. Gallo
DOI: https://doi.org/10.1177/154405910808700903
2008-09-01
Journal of Dental Research
Abstract:Occlusal splints are used for the management of temporomandibular disorders, although their mechanism of action remains controversial. This study investigated whether insertion of an occlusal splint leads to condyle-fossa distance changes, and to mandibular rotation and/or translation. By combining magnetic resonance images with jaw tracking (dynamic stereometry), we analyzed the intra-articular distances of 20 human temporomandibular joints (TMJs) before and after insertion of occlusal splints of 3 mm thickness in the first molar region. For habitual closure, protrusion, and laterotrusion in the contralateral joint, occlusal splints led to minor—yet statistically significant—increases of global TMJ space and to larger increases at defined condylar areas. Condylar end rotation and translation in habitual closure were reduced. Hence, the insertion of a 3-mm-thick occlusal splint led to a change in the topographical condyle-fossa relationship, and therefore to a new distribution of contact areas between joint surfaces.
dentistry, oral surgery & medicine
What problem does this paper attempt to address?