Brno University of Technology Smartphone PPG Database (BUT PPG): Annotated Dataset for PPG Quality Assessment and Heart Rate Estimation

Andrea Nemcova,Enikö Vargova,Radovan Smisek,Lucie Marsanova,Lukas Smital,Martin Vitek
DOI: https://doi.org/10.1155/2021/3453007
2021-09-06
BioMed Research International
Abstract:To the best of our knowledge, there is no annotated database of PPG signals recorded by smartphone publicly available. This article introduces Brno University of Technology Smartphone PPG Database (BUT PPG) which is an original database created by the cardiology team at the Department of Biomedical Engineering, Brno University of Technology, for the purpose of evaluating photoplethysmographic (PPG) signal quality and estimation of heart rate (HR). The data comprises 48 10-second recordings of PPGs and associated electrocardiographic (ECG) signals used for determination of reference HR. The data were collected from 12 subjects (6 female, 6 male) aged between 21 and 61. PPG data were collected by smartphone Xiaomi Mi9 with sampling frequency of 30 Hz. Reference ECG signals were recorded using a mobile ECG recorder (Bittium Faros 360) with a sampling frequency of 1,000 Hz. Each PPG signal includes annotation of quality created manually by biomedical experts and reference HR. PPG signal quality is indicated binary: 1 indicates good quality for HR estimation, 0 indicates signals where HR cannot be detected reliably, and thus, these signals are unsuitable for further analysis. As the only available database containing PPG signals recorded by smartphone, BUT PPG is a unique tool for the development of smart, user-friendly, cheap, on-the-spot, self-home-monitoring of heart rate with the potential of widespread using.
biotechnology & applied microbiology,medicine, research & experimental
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: currently, there is a lack of publicly available databases of photoplethysmography (PPG) signals recorded by smartphones with annotations, which restricts the research and development of PPG signal quality assessment and heart rate (HR) estimation algorithms. Specifically: 1. **PPG Signal Quality Assessment**: Existing PPG signal quality assessment methods lack standardized and reliable benchmark datasets, making it difficult to verify and improve these methods. 2. **Accuracy of Heart Rate Estimation**: When estimating heart rate from mobile and wearable devices, accuracy and reliability remain a challenge due to multiple factors (such as physical activity, improper wearing, etc.). 3. **Lack of Annotated Data**: There is no publicly available database of PPG signals recorded by smartphones and annotated by experts, which hinders the development of related research. To solve these problems, this study introduced the Brno University of Technology Smartphone PPG Database (BUT PPG). This database contains 48 10 - second PPG signals and their corresponding ECG signals for determining the reference heart rate. All PPG signals are manually annotated by biomedical experts to assess their quality and the accuracy of heart rate estimation. Specific annotations include: - **Binary Quality Label**: 1 represents a high - quality signal suitable for heart rate estimation; 0 represents a low - quality signal not suitable for further analysis. - **Heart Rate Label**: The reference heart rate calculated based on the ECG signal. By providing such a unique and detailed database, researchers can better develop and evaluate PPG signal processing algorithms, especially in intelligent, user - friendly, inexpensive, and instant home heart rate self - monitoring applications.