Quantitative Determination of Non-Haem Iron and Ferritin Iron in Bone Marrow Using Flameless Atomic Absorption Spectrophotometry. A Comparative Study on the Cytological and Chemical Determination of the Bone Marrow Iron Content

M P van Dieijen-Visser,G J Marell,J L Coenen,P J Brombacher,M. P. van Dieijen-Visser,G. J. Marell,J. L. L. M. Coenen,P. J. Brombacher
DOI: https://doi.org/10.1515/cclm.1991.29.6.381
1991-01-01
Abstract:A method for non-haem iron analysis in bone marrow aspirates using graphite furnace atomic absorption spectrophotometry has been developed. Bone marrow aspirates were obtained from patients with various disorders. A good correlation is observed between chemical and cytological assessment of total non-haem iron in bone marrow. An intra-assay coefficient of variation of 9.0% was observed. The ferritin-iron concentration was also determined and a CVduplo of 11% was found. The ferritin iron concentration increased with an increasing total iron content until saturation of ferritin appeared to be reached at about 3 g ferritin per kg protein. It was concluded that the quantitative determination of bone marrow iron can be of value in the diagnosis and investigation of both hypo- and hyper-ferraemic disorders.
medical laboratory technology
What problem does this paper attempt to address?