Development and Evaluation of a New Electrical Submersible Pump for High Viscosity Environments

Laura Matheus,Oscar Anaya,Sebastián Izquierdo,Miguel Garzón,Woon Lee
DOI: https://doi.org/10.2118/206265-ms
2021-09-15
Abstract:Abstract Conventional methods of Heavy Oil production have either delivered low recovery factors or have involved costly thermal projects. With low oil prices the new norm, Operators need to maximize their recovery factors whilst controlling CAPEX required to exploit their assets. This paper presents a new approach to lifting heavy/viscous oil with a Pump design that will allow Operators to increase overall field production with reduced energy consumption. A trial was conducted in Colombia in a harsh field (high viscosity, low water cut, high temperature and high gas production) that had challenged conventional artificial lift systems as Electrical submersible pumps and progressive cavity pumps. Several strategies (light oil injection, high capacity equipment, solvents injection at surface) had been implemented to overcome fluid viscosities 6,000 cP @ 150 °F at dead oil conditions and a mean of 250 cp inside the pump, with excellent short and medium-term results but system hydraulic efficiency and energy consumption were still below expectations. A new pump has been specially designed for the fluid conditions previously described, with the main objective of reduce the friction losses inside the pump stage increasing the overall efficiency and reducing energy consumption. Initial trial results have fulfilled the study's objectives, overcoming the issues previously experienced with ESP operations in this field. Designed to handle heavy, high viscosity oil, this study has demonstrated that there is significant economic benefit through savings and improved efficiencies and, in addition, ESP capital cost savings. Previously, oversized units were routinely used to deliver the required flow and pump power but by optimizing the sizing of the ESP system, it is possible to select pumps with fewer stages and lower horsepower motors to suit the new requirements. Data from the field tests have delivered encouraging results. The pump has operated smoothly since installation and, in comparison to standard pump, has reduced energy consumption (savings of 10-15%) and shown a 15-20% increase in pump efficiency. The Operator has reasonable optimistic expectations for future installations in this field in all applicable wells.
What problem does this paper attempt to address?