Relaxivity of gadolinium complexes detected by atomic magnetometry

David J. Michalak,Shoujun Xu,Thomas J. Lowery,C. W. Crawford,Micah Ledbetter,Louis-S. Bouchard,David E. Wemmer,Dmitry Budker,Alexander Pines
DOI: https://doi.org/10.1002/mrm.22811
2011-03-23
Magnetic Resonance in Medicine
Abstract:Laser atomic magnetometry is a portable and low-cost yet highly sensitive method for low magnetic field detection. In this work, the atomic magnetometer was used in a remote-detection geometry to measure the relaxivity of aqueous gadolinium-diethylenetriamine pentaacetic acid Gd(DTPA) at the Earth's magnetic field (40 μT). The measured relaxivity of 9.7±2.0 s(-1) mM(-1) is consistent with field-cycling experiments measured at slightly higher magnetic fields, but no cryogens or strong and homogeneous magnetic field were required for this experiment. The field-independent sensitivity of 80 fT Hz(-1/2) allowed an in vitro detection limit of ∼10 μM Gd(DTPA) to be measured in aqueous buffer solution. The low detection limit and enhanced relaxivity of Gd-containing complexes at Earth's field motivate continued development of atomic magnetometry toward medical applications.
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?