Optimization of urban wastewater treatment plants process with low C/N ratio
L Zheng,G M Xu,J Chen,B Chen,Z Lv,Y A Yang
DOI: https://doi.org/10.1088/1755-1315/39/1/012017
2016-08-01
IOP Conference Series: Earth and Environmental Science
Abstract:In southern China, the inflow of water to wastewater treatment plants has a lower concentration of organic matter. This causes treatment plants to face issues in the denitrification and phosphorus removal processes such as deficient carbon sources, high energy consumption, and unstable nitrogen removal. To resolve these issues, we propose the reconstruction of the internal reflux port, improvement of the internal reflux ratio to 200%, the addition of carbon source to anoxic zone, and the addition of phosphorus removal agents in secondary settling tank. The results of study show significantly improved efficiency of nitrogen and phosphorus removal, which ensures the stability of subsequent supply of reused water.
English Else
What problem does this paper attempt to address?