Ultrasensitive Competitive Lateral Flow Immunoassay with Visual Semiquantitative Inspection and Flexible Quantification Capabilities
Daquan Li,Mei Huang,Ziyu Shi,Liang Huang,Jiening Jin,Chenxing Jiang,Wenbo Yu,Zhiyong Guo,Jing Wang
DOI: https://doi.org/10.1021/acs.analchem.1c05364
IF: 7.4
2022-02-02
Analytical Chemistry
Abstract:Antibiotics abuse has caused various problems threatening human health and ecological environment. Monitoring antibiotics residual levels is of great significance, yet still challenging for quantitative point-of-need testing with high-sensitivity and visual capability. Here we developed a competitive lateral flow immunoassay (CLFIA) platform with flexible readout for enrofloxacin (ENR), a regularly added antibiotic. To overcome the limitation of low sensitivity of traditional colloidal gold-based CLFIA, the three-dimensionally assembled gold nanoparticles (AuNPs) within dendritic silica scaffold were fabricated as signal reporters. The assembly structure effectively retained the intrinsic absorption features of hydrophobic AuNPs and greatly enhanced the light extinction ability of a single label for signal amplification. The obtained CLFIA strips can not only achieve qualitative screening of ENR at a very low concentration by naked eye (cutoff value: 0.125 ng/mL), but also enable ultrasensitive quantification of ENR by an optical scanner (limit of detection: 0.00195 ng/mL) or a smartphone (limit of detection: 0.0078 ng/mL). Moreover, to elaborate the visual inspection degree of CLFIA against traditional yes/no interpretation, a novel multirange gradient CLFIA strip was prepared for visually semiquantitative identification of ENR with four concentration ranges. The novel CLFIA platform demonstrated sensitive, specific, and reliable determination of ENR with flexible signal readout and provides a potential and invigorating pathway to point-of-need immunoassay of antibiotics.The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acs.analchem.1c05364.Materials and reagents, experimental section, TEM image, and UV–vis spectrum of AuNPs, relationships between AuNPs loading content and AuNPs feeding content for dSiO2, relationship of the ST and B/B0 values with types of NC membrane, photographs of optimizations on experimental parameters for CLFIA strips, quantitative calibration between the logarithms of ENR concentration and IT/IC of the multirange gradient CLFIA strips, stability of CLFIA strips, correlation analysis of the detection results between optical scanner and smartphone, the images and quantitative calibration curves of real samples, supplementary table of a summary for ENR detection by different methods (PDF)This article has not yet been cited by other publications.
chemistry, analytical