Hysteroscopic Metroplasty using Holmium YAG Laser for Treatment of Septate Uterus

Anuja V Kulkarni,Vishvas M Kulkarni,Rameshwari Alahabade,Prachi D Ruikar,Rajashree Mahajan,Tejal Kulkarni,Dipti Giri,N. Nandana
DOI: https://doi.org/10.1016/j.jmig.2024.01.010
IF: 4.314
2024-02-03
Journal of Minimally Invasive Gynecology
Abstract:Objective To demonstrate the safety, efficacy, and ease of hysteroscopic metroplasty using Holmium YAG Laser for treatment of septate uterus. Design Stepwise demonstration of surgical technique with narrated video footage. Setting Septate uterus is the most common type of uterine anomaly. The incidence of uterine septum in women presenting with infertility and recurrent abortions is 15.4% (1)(2) . Hysteroscopic septal incision is associated with improvement in live-birth rate in these women (3) . Hysteroscopic metroplasty for septate uterus can be done with the use of scissors and energy sources like monopolar and bipolar electrosurgery and lasers. Holmium YAG (Ho: YAG) laser is commonly used by urologists for various surgeries because of its "Swiss Army Knife" action of cutting, coagulation & vaporization (4) . Holmium YAG laser is known for its precision. It causes lesser depth of tissue injury and necrosis and minimal collateral thermal damage as compared to the electrosurgical devices and other lasers used for hysteroscopic surgery (5)(6)(7)(8) . This is advantageous in hysteroscopic metroplasty as it reduces the risk of uterine perforation during surgery and hence uterine rupture in the subsequent pregnancy. Reduced collateral damage to the surrounding endometrium helps promote early endometrial healing and prevent post operative intrauterine adhesions. A 28-year-old patient with history of two spontaneous abortions came to our hospital for investigations. 3D trans vaginal sonography of the patient showed presence of partial septate uterus with a fundal indentation of 1.5 cm. Intervention Diagnostic hysteroscopy followed by septal incision using Ho: YAG laser was planned. We used a 2.9 mm BETTOCHI Hysteroscope (Karl Storz SE & Co.) with a 5 mm operative sheath. Normal saline was used as the distending medium and the intrauterine pressure was maintained at 80–100 mm of Hg. The procedure was done under total intravenous anaesthesia using Inj. Propofol. Vaginoscopic entry into the uterus (without any cervical dilatation) showed evidence of a partial uterine septum with tubal ostia on either side of the septum. A 400-micron quartz fibre was passed through a laser guide into the 5 Fr working channel of the operative hysteroscope. Ho:YAG laser (Auriga XL 50-Watt, Boston Scientific) with power settings of 15 Watts (1500mJ energy at 10Hz) was used. Incision of the septum was started at the apex of the septum in the midline and continued in a horizontal manner from side to side towards the base. Incision of the septum is continued till the tip of the hysteroscope can move freely from one ostium to the other. The operative time was 12 minutes. There were no intra or post operative complications. Postoperative oestrogen therapy was given for two months in the form of Oestradiol Valerate 2 mg (Tab. Progynova, Zydus Cadila) 12 hourly orally for 25 days and Medroxyprogesterone Acetate 10 mg (Tab. Meprate, Serum Institute of India. Ltd) 12 hourly orally added in the last 5 days (9) . 3D trans vaginal ultrasound was done on D 8 of menses. It showed a triangular uterine cavity with a very small fundal indentation of 0.37cms. A second look hysteroscopy which was done on D 9 of menses showed an uterine cavity of good shape and size (10) . Few fundal adhesions were seen and they were incised using Ho:YAG laser.The patient conceived 5 months after the primary surgery and delivered by caesarean section at 38 weeks, giving birth to a healthy baby of 2860 grams. There were no complications during her pregnancy and delivery. A comparative study is essential to prove its advantages over other energy sources for this surgery. Conclusion Hysteroscopic metroplasty using Ho:YAG Laser for treatment of septate uterus is a simple, precise, safe, and effective procedure.
obstetrics & gynecology
What problem does this paper attempt to address?