Task-based Assessment of Deep Networks for Sinogram Denoising with A Transformer-based Observer

Yongyi Shi,Ge Wang,Xuanqin Mou
DOI: https://doi.org/10.48550/arXiv.2212.12838
IF: 4.506
2022-12-25
Medical Physics
Abstract:A variety of supervise learning methods are available for low-dose CT denoising in the sinogram domain. Traditional model observers are widely employed to evaluate these methods. However, the sinogram domain evaluation remains an open challenge for deep learning-based low-dose CT denoising. Since each lesion in medical CT images corresponds to a narrow sinusoidal strip in sinogram domain, here we proposed a transformer-based model observer to evaluate sinogram domain supervised learning methods. The numerical results indicate that our transformer-based model well-approximates the Laguerre-Gauss channelized Hotelling observer (LG-CHO) for a signal-known-exactly (SKE) and background-known-statistically (BKS) task. The proposed model observer is employed to assess two classic CNN-based sinogram domain denoising methods. The results demonstrate a utility and potential of this transformer-based observer model in developing deep low-dose CT denoising methods in the sinogram domain.
What problem does this paper attempt to address?
This paper attempts to address the problem of how to evaluate the effectiveness of deep learning methods for denoising in the sinogram domain in low-dose CT (Computed Tomography) imaging. Specifically, traditional model observers are widely used to evaluate supervised learning methods, but in the sinogram domain, the evaluation of these methods remains an open challenge. This is because each lesion in a CT image corresponds to a narrow sinusoidal strip in the sinogram domain, making it difficult for traditional convolutional neural network (CNN)-based methods to effectively extract local structural information. To address this challenge, the paper proposes a transformer-based model observer for evaluating supervised learning methods in the sinogram domain. This model observer can well approximate the Laguerre-Gaussian Channelized Hotelling Observer (LG-CHO) and is suitable for tasks with known exact signals (SKE) and known statistical backgrounds (BKS). Through numerical experiments, the paper validates the effectiveness and potential application value of this model observer and applies it to evaluate two classic CNN-based sinogram domain denoising methods (RED-CNN and DnCNN). In summary, the main goal of the paper is to develop a new transformer-based model observer to more accurately evaluate deep learning denoising methods in the low-dose CT sinogram domain, thereby improving image quality and lesion detection performance.