Atmospheric radioxenon isotope monitoring in Beijing after the Fukushima nuclear power plant accident

Chongyang Zhou,Guoqing Zhou,Shujuan Feng,Yuren Jin,Xinhua Zhao,Ziwei Cheng,Xiongliang Huang,Hui Xu,Xu Zhou
DOI: https://doi.org/10.1016/j.apradiso.2012.10.007
IF: 1.787
2013-02-01
Applied Radiation and Isotopes
Abstract:A custom-made, on-site radioxenon sampling, separation and monitoring system was used to monitor atmospheric radioxenon concentrations in Beijing, released from the Fukushima Daiichi nuclear power plant after the earthquake of 11 March 2011. The results show that (133)Xe concentrations ranged from 393 to 26 mBq/m(3) from 12 to 27 April 2011, and those of (131 m)Xe were 84 and 40 mBq/m(3) on 13 and 15 April 2011, respectively. The highest dose rate caused by (133)Xe was 2 × 10(-5)mSv/yr, and the average (133)Xe/(131 m)Xe ratio was 3.8 ± 0.4.
radiology, nuclear medicine & medical imaging,nuclear science & technology,chemistry, inorganic & nuclear