Film-Cooling Performance with Various Hole Length to Diameter Ratios for Cylindrical and Laidback Fan-Shaped Holes with an Inlet Groove

Jisu Park,Jun-Hee Kim,Changwoo Kang
DOI: https://doi.org/10.1007/s11630-024-2060-7
IF: 2.013
2024-12-12
Journal of Thermal Science
Abstract:The influence of the hole length-to-diameter ratio on film-cooling performance is numerically investigated for a cylindrical hole and laidback fan-shaped hole with an inlet groove. Numerical analysis of film-cooling is conducted by solving three-dimensional Reynolds-averaged Navier-Stokes equations (RANS) with a Realizable k - ε turbulence model. Rectangular and triangular grooves are applied to the inlet of cylindrical and laidback fan-shaped holes. The ratio of the hole length ( L ) to the diameter ( D ), i.e., L / D , is varied between 6–12 at blowing ratios ( M ) of 0.5 to 1.5 for the cylindrical hole and 0.5 to 3.0 for the laidback fan-shaped hole. For cylindrical holes with an inlet groove, the film-cooling effectiveness decreases as the L / D increases, regardless of the blowing ratio. However, in the case of laidback fan-shaped holes, the cooling performance with the length-to-diameter ratios shows different tendencies for each blowing ratio. At low blowing ratios ( M =1.0), relatively high effects were observed with more than 5% increases in the effectiveness at L / D =10 and 12 compared to that of L / D =6. However, the performance is maximized at L / D =8 under high-blowing-ratio conditions ( M =3.0). The cooling efficiency is enhanced up to 148% for square grooves and 124% for triangle grooves compared to those of L / D =6.
engineering, mechanical,thermodynamics
What problem does this paper attempt to address?