Photon-Counting Detector CT Virtual Monoenergetic Images in Cervical Trauma Imaging—Optimization of Dental Metal Artifacts and Image Quality

Daniel Dillinger,Daniel Overhoff,Matthias F. Froelich,Hanns L. Kaatsch,Christian Booz,Achim Hagen,Thomas J. Vogl,Stefan O. Schönberg,Stephan Waldeck
DOI: https://doi.org/10.3390/diagnostics14060626
IF: 3.6
2024-03-16
Diagnostics
Abstract:Objectives: The aim of this study was to analyze the extent of dental metal artifacts in virtual monoenergetic (VME) images, as they often compromise image quality by obscuring soft tissue affecting vascular attenuation reducing sensitivity in the detection of dissections. Methods: Neck photon-counting CT datasets of 50 patients undergoing contrast-enhanced trauma CT were analyzed. Hyperattenuation and hypoattenuation artifacts, muscle with and without artifacts and vessels with and without artifacts were measured at energy levels from 40 keV to 190 keV. The corrected artifact burden, corrected image noise and artifact index were calculated. We also assessed subjective image quality on a Likert-scale. Results: Our study showed a lower artifact burden and less noise in artifact-affected areas above the energy levels of 70 keV for hyperattenuation artifacts (conventional polychromatic CT images 1123 ± 625 HU vs. 70 keV VME 1089 ± 733 HU, p = 0.125) and above of 80 keV for hypoattenuation artifacts (conventional CT images −1166 ± 779 HU vs. 80 keV VME −1170 ± 851 HU, p = 0.927). Vascular structures were less hampered by metal artifacts than muscles (e.g., corrected artifact burden at 40 keV muscle 158 ± 125 HU vs. vessels −63 ± 158 HU p < 0.001), which was also reflected in the subjective image assessment, which showed better ratings at higher keV values and overall better ratings for vascular structures than for the overall artifact burden. Conclusions: Our research suggests 70 keV might be the best compromise for reducing metal artifacts affecting vascular structures and preventing vascular contrast if solely using VME reconstructions. VME imaging shows only significant effects on the general artifact burden. Vascular structures generally experience fewer metal artifacts than soft tissue due to their greater distance from the teeth, which are a common source of such artifacts.
medicine, general & internal
What problem does this paper attempt to address?
The paper attempts to address the issue of image artifacts caused by dental metal implants affecting image quality in neck trauma imaging. Specifically, the paper focuses on the effectiveness of Virtual Monoenergetic (VME) images in reducing these metal artifacts, particularly in the assessment of vascular structures and muscle tissue. ### Main Research Objectives: 1. **Analyze the extent of metal artifacts**: Study how VME images at different energy levels affect high-density and low-density artifacts caused by dental metal implants. 2. **Optimize image quality**: Evaluate the effectiveness of VME images in reducing metal artifacts and improving image quality, especially in the visualization of vascular structures and muscle tissue. 3. **Determine the optimal energy threshold**: Identify the best balance point between reducing metal artifacts and maintaining vascular contrast. ### Research Background: - **Clinical Need**: In emergency rooms, severely injured patients often require CT scans to check for trauma-related injuries. However, dental metal implants frequently cause image artifacts, affecting the visualization of soft tissues and blood vessels, thereby reducing diagnostic quality. - **Existing Technology**: Traditional CT techniques reduce metal artifacts by adjusting parameters such as tube voltage, current, and collimators, but these methods may increase radiation dose. Dual-energy CT technology and Virtual Monoenergetic Imaging (VME) have shown potential in reducing metal artifacts. ### Research Methods: - **Study Subjects**: 50 patients undergoing trauma CT scans with significant dental metal artifacts. - **Imaging Protocol**: Scans were performed using a first-generation photon-counting detector CT (PCD-CT) and VME images were reconstructed at different energy levels (40 keV to 190 keV). - **Image Analysis**: Image quality was assessed through objective measurements (such as attenuation, noise, corrected artifact burden, and artifact index) and subjective evaluations (using a Likert scale). ### Key Findings: - **High-Density Artifacts**: At energy levels above 70 keV, VME images showed lower artifact burden and noise. - **Low-Density Artifacts**: At energy levels above 80 keV, VME images showed lower artifact burden and noise. - **Vascular Structures**: Vascular structures were less affected by metal artifacts as they are farther from the teeth. - **Subjective Evaluation**: Higher energy levels resulted in higher subjective image quality scores, particularly for the assessment of vascular structures. ### Conclusion: - **Optimal Energy Threshold**: 70 keV may be the best balance point for reducing metal artifacts and maintaining vascular contrast. - **Overall Effectiveness**: VME imaging shows significant effectiveness in reducing metal artifacts, especially in vascular structures. Through these findings, the authors hope to provide clinicians with an effective tool to improve the quality and diagnostic accuracy of neck trauma imaging.