Volumetric dried blood spots for determination of phosphatidylethanol: Validation of a liquid chromatography tandem masspectrometry method and clinical application

Olof Beck,Miguel Barroso,Sigurd Hermansson,Cristopher Widén,Christer Wallin,Cecilia Nilsson‐Wallmark,Andrea de Bejczy
DOI: https://doi.org/10.1002/dta.3695
2024-04-27
Drug Testing and Analysis
Abstract:Phosphatidylethanol, a specific alcohol biomarker, measured in dried blood spots was the focus of this work. A liquid chromatography tandem mass spectrometry method was developed, validated, and applied. The blood sampling used a volumetric DBS device. The volumetric device gave accurate and precise quantifications and the dried capillary blood gave the same results as that of venous blood. Phosphatidylethanol (PEth) measurement in whole blood samples is established as a specific alcohol biomarker with clinical and forensic applications. Establishment of dried blood spots (DBSs) as a specimen for PEth determination offers several advantages and was the focus of this work. A liquid chromatography tandem mass spectrometry method using a 96‐well format for sample preparation was developed and validated. PEth was extracted from DBSs by using isopropanol containing PEth‐d5 as internal standard. The blood sampling used a commercial volumetric DBS device having a phosholipase D inhibitor incorporated to stop continuous PEth formation. The method quantified PEth in the range of 0.05–10 μmol/L, with a bias and imprecision of less than 15%. In a clinical study (n = 25) using fingerprick blood, the volumetric device offered more precise quantifications (CV 4.6%) compared with the Whatman 903 Protein Saver card device (CV 16.6%). In another clinical study (n = 48), the use of dried venous and capillary blood, and liquid venous blood was compared under real‐life conditions with samples sent by postal service. The capillary and venous DBS samples gave identical results while the liquid blood gave slightly higher values. Calculation of elimination half‐life (PEth 16:0/18:1) in 31 cases based on two consecutive samples with 2–9 days in between gave results (mean 6.2 days) that agree with literature but several cases with values over 10 days. In conclusion, this study demonstrates that volumetric DBS is a valid specimen for determination of PEth blood concentrations, offering several advantages.
pharmacology & pharmacy,biochemical research methods,chemistry, analytical
What problem does this paper attempt to address?