Automatic Current Limit Strategy for LLC DC-DC Converter for Overload Operation

Xiao Yang,Deshang Sha
DOI: https://doi.org/10.1109/tpel.2024.3397621
IF: 5.967
2024-06-22
IEEE Transactions on Power Electronics
Abstract:LLC dc–dc converter is widely used, but its current suppression under overload operation is a concerned issue. In the previous work, the working conditions in which the switching frequency is lower than the resonant frequency and phase shift (PS) control under overload operation are not mentioned. In this article, comprehensive and universal geometric analysis is given under these conditions. The relationship of resonant current, normalized output voltage, switching frequency and PS angle is analyzed comprehensively in facing various working conditions with state-plane analysis. These analyses can be referenced in researches on controlling the peak value of resonant current. Experimental results are demonstrated on a 300 W LLC converter to verify the effectiveness of the analysis.
engineering, electrical & electronic
What problem does this paper attempt to address?