Clinical uncertainty in large vessel occlusion ischemic stroke: does automated perfusion imaging make a difference? An intra-rater and inter-rater agreement study
Jose Danilo Bengzon Diestro,Robert Fahed,Abdelsimar Tan Omar,Christine Hawkes,Eef J Hendriks,Clare Enriquez,Muneer Eesa,Grant Stotts,Hubert Lee,Shashank Nagendra,Alexandre Poppe,Célina Ducroux,Timothy Lim,Karl Narvacan,Michael Rizzuto,Afra Alfalahi,Hidehisa Nishi,Pragyan Sarma,Ze'ev Itsekson Hayosh,Katrina Ignacio,William Boisseau,Eduardo Pimenta Ribeiro Pontes Almeida,Anass Benomar,Mohammed A Almekhlafi,Genvieve Milot,Aviraj Deshmukh,Kislay Kishore,Donatella Tampieri,Jeffrey Wang,Abhilekh Srivastava,Daniel Roy,Federico Carpani,Nima Kashani,Claudia Candale-Radu,Nishita Singh,Maria Bres Bullrich,Robert Sarmiento,Ryan T Muir,Carmen Parra-Fariñas,Stephanie Reiter,Yan Deschaintre,Ravinder-Jeet Singh,Vivek Bodani,Aristeidis Katsanos,Ronit Agid,Atif Zafar,Vitor M Pereira,Julian Spears,Thomas R Marotta,Pascal Djiadeu,Sunjay Sharma,Forough Farrokhyar
DOI: https://doi.org/10.1136/jnis-2023-021429
IF: 4.8
2024-03-07
Journal of NeuroInterventional Surgery
Abstract:Background Limited research exists regarding the impact of neuroimaging on endovascular thrombectomy (EVT) decisions for late-window cases of large vessel occlusion (LVO) stroke. Objective T0 assess whether perfusion CT imaging: (1) alters the proportion of recommendations for EVT, and (2) enhances the reliability of EVT decision-making compared with non-contrast CT and CT angiography. Methods We conducted a survey using 30 patients drawn from an institutional database of 3144 acute stroke cases. These were presented to 29 Canadian physicians with and without perfusion imaging. We used non-overlapping 95% confidence intervals and difference in agreement classification as criteria to suggest a difference between the Gwet AC1 statistics (κ G ). Results The percentage of EVT recommendations differed by 1.1% with or without perfusion imaging. Individual decisions changed in 21.4% of cases (11.3% against EVT and 10.1% in favor). Inter-rater agreement (κ G ) among the 29 raters was similar between non-perfusion and perfusion CT neuroimaging (κ G =0.487; 95% CI 0.327 to 0.647 and κ G =0.552; 95% CI 0.430 to 0.675). The 95% CIs overlapped with moderate agreement in both. Intra-rater agreement exhibited overlapping 95% CIs for all 28 raters. κ G was either substantial or excellent (0.81–1) for 71.4% (20/28) of raters in both groups. Conclusions Despite the minimal difference in overall EVT recommendations with either neuroimaging protocol one in five decisions changed with perfusion imaging. Regarding agreement we found that the use of automated CT perfusion images does not significantly impact the reliability of EVT decisions for patients with late-window LVO.
surgery,neuroimaging