Selection criteria for circular collimator- vs. Multileaf collimator-based plans in robotic stereotactic radiotherapy for brain metastases and benign intracranial disease: Impact of target size, shape complexity, and proximity to at-risk organs

Takeshi Takizawa,Satoshi Tanabe,Hisashi Nakano,Satoru Utsunomiya,Katsuya Maruyama,Motoki Kaidu,Hiroyuki Ishikawa,Kiyoshi Onda
DOI: https://doi.org/10.1016/j.ejmp.2024.104852
IF: 3.119
2024-11-02
Physica Medica
Abstract:Highlights • Selection criteria for circular cone and MLC for CyberKnife SRS were evaluated. • A mathematical score was adapted to assess the quality of the dose distribution. • MLC is recommended when the tumor radius exceeds 7.6 mm in metastatic brain tumors. • In the benign brain tumors, MLC is recommended when the tumor radius exceeds 17.5 mm. • Collimator selection based on these criteria improves plan quality of CyberKnife SRS. Purpose This study aimed to determine the selection criteria for circular collimator (CC)- and multileaf collimator (MLC)-based stereotactic radiosurgery (SRS)/stereotactic radiotherapy (SRT) plans for brain metastases (BM) and benign intracranial disease (BID) in terms of geometric parameters using CyberKnife (CK). Methods Forty-eight and eighty-five patients with BM and BID, respectively, were included. Two plans using CC and MLC were created for each case. Six dosimetric parameters and mathematical scores (MS) were extracted from each plan to assess plan quality. Two geometric parameters in BM—equivalent radius (rGTV) and sphericity index (SI) of the gross tumor volume—and three in BID—rGTV, SI, and the distance between the GTV and organ at risk (dOAR)—were calculated. Their effect on the superiority of CC– or MLC-based plans in terms of dosimetric parameters and MS was evaluated using multiple regression analysis. Results The rGTV was associated with improved dosimetric parameters of MLC-based plans, especially the GTV conformity in BM and BID cases (β: 0.70 and 0.51) and the OAR sparing in BM cases (β: 0.82), where β represents the regression coefficient. Based on the MS, where the weights for the GTV coverage and OAR sparing were equal, the thresholds at which the MLC-based plans become comparable or superior to the CC-based plans in BM and BID were rGTV > 7.6 and >17.5 mm, respectively. Meanwhile, SI and dOAR were weakly correlated (β ≤ 0.30). Conclusions In SRS/SRT plans for BM and BID cases using CyberKnife, geometric parameters, especially rGTV, must be considered when selecting CC or MLC.
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?