Ying Yang,Yuanqing Ma,Jonathan F. Berengut,Lawrence K. Lee,Richard D. Tilley,Katharina Gaus,J. Justin Gooding
Abstract:Stochastic optical reconstruction microscopy (STORM) allows wide-field imaging with single-molecule resolution by calculating the coordinates of individual fluorophores from the separation of fluorophore emission in both time and space. Such separation is achieved by photoswitching the fluorophores between a long-lived OFF state and an emissive ON state. Although STORM can image single molecules, molecular counting remains challenging due to undercounting errors from photobleached or overlapping dyes and overcounting artefacts from the repetitive random blinking of dyes. Here we show that fluorophores can be electrochemically switched for STORM imaging (EC-STORM), with excellent control over the switching kinetics, duty cycle and recovery yield. Using EC-STORM, we demonstrate molecular counting by using electrochemical potential to control the photophysics of dyes. The random blinking of dyes is suppressed by a negative potential but the switching-ON event can be activated by a short positive-potential pulse, such that the frequency of ON events scales linearly with the number of underlying dyes. We also demonstrate EC-STORM of tubulin in fixed cells with a spatial resolution as low as ~28 nm and counting of single Alexa 647 fluorophores on various DNA nanoruler structures. This control over fluorophore switching will enable EC-STORM to be broadly applicable in super-resolution imaging and molecular counting.
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to effectively control the on - off state of fluorophores in the single - molecule - resolution imaging technique STORM to achieve more accurate molecular counting. Specifically, the authors propose a new method - electrochemically - controlled fluorophore blinking (EC - STORM). By means of electrochemistry, the conversion between the "on" and "off" states of fluorophores is precisely controlled, thus solving the overcounting and undercounting problems existing in the traditional STORM technique.
### Main problems
1. **Overcounting problem**: Due to the random blinking of fluorophores, a single fluorophore is misidentified as multiple molecules.
2. **Undercounting problem**: Due to photobleaching or overlapping fluorophores, some molecules cannot be detected.
### Solutions
- **Electrochemical control**: The on - off state of fluorophores is controlled by applying different potentials. A negative potential can switch the fluorophore to the "off" state, and a positive potential pulse can switch it back to the "on" state.
- **Precisely controlling the switching frequency**: By adjusting the potential, the switching frequency of fluorophores can be precisely controlled, thereby reducing the influence of random blinking.
- **Improving the accuracy of molecular counting**: Through electrochemical control, the precise switching of fluorophores is achieved, making molecular counting more accurate.
### Experimental verification
- **Fluorophore switching kinetics**: The on - rate constant \( k_{\text{on}} \) and off - rate constant \( k_{\text{off}} \) of fluorophores under different potentials were measured to verify the effectiveness of electrochemical control.
- **Duty - cycle adjustment**: By changing the potential, the duty - cycle of fluorophores (i.e., the proportion of time that the fluorophore is in the "on" state) can be adjusted within a wide range, thereby optimizing the imaging quality.
- **Recovery rate test**: Experiments show that electrochemical control can achieve a 100% fluorophore recovery rate, while traditional photochemical control can only recover about 67% of fluorophores.
### Application examples
- **Two - dimensional and three - dimensional imaging**: Through electrochemical control, EC - STORM shows higher resolution and fewer artifacts in both two - dimensional and three - dimensional imaging.
- **Single - molecule counting**: Through electrochemical control, the accurate counting of fluorophores on DNA nanorulers has been successfully achieved, verifying the application potential of this method in molecular counting.
In conclusion, by introducing the electrochemical control method, this paper significantly improves the accuracy and reliability of STORM imaging, providing a new solution for single - molecule - resolution imaging and molecular counting.