Shear behavior of square ultra-high performance concrete-filled high-strength steel tube members

Zhichao Lai,Jiali Wang,Xiwen Chen,Dong Li
DOI: https://doi.org/10.1016/j.jcsr.2023.108330
IF: 4.349
2023-11-17
Journal of Constructional Steel Research
Abstract:High-strength steel and ultra-high-performance concrete (UHPC) can increase structural resistance and reduce material consumption efficiently. However, current design specifications do not permit the use of them in concrete-filled steel tube members due to the lack of research. To address it, this paper experimentally investigates the shear behavior of square ultra-high performance concrete-filled high-strength steel tube (referred to as C u FT h hereafter) members. A total of 20 C u FT h specimens were tested, considering the effects of the span-to-depth ratio, width-to-thickness ratio of the steel tube, yield stress of steel, and fiber volume content of UHPC. The test results showed that: (i) the failure mode was governed by the shear span-to-depth ratio ( a/H ), including shear failure ( a/H = 0.2 or 0.5) and combined shear-flexural failure ( a/H = 0.8 or 1.0); (ii) the shear strength increased with decreasing shear span-to-depth ratio and the width-to-thickness ratio of the steel tube; (iii) increasing the yield stress of steel and fiber volume content of UHPC improved the shear strength. The applicability of current specifications for estimating the shear strength of square C u FT h members was evaluated. It was shown that CECS 28 (CECS 2012) had the most reasonable estimation.
construction & building technology,engineering, civil
What problem does this paper attempt to address?