On–Off–On Fluorescent Chemosensors Based on N/P-Codoped Carbon Dots for Detection of Microcystin-LR
Xiaoyan Wang,Jialuo Yu,Wan Ji,Maryam Arabi,Longwen Fu,Bowei Li,Lingxin Chen
DOI: https://doi.org/10.1021/acsanm.1c00921
IF: 6.14
2021-07-13
ACS Applied Nano Materials
Abstract:The sensing of microcystin-LR (MC-LR) as a nonfluorescent species is still challenging since it has a negligible influence on the emission of fluorescent nanomaterials. Herein, a well-defined "on–off–on" indirect chemosensing strategy is developed by means of nitrogen/phosphorus-codoped carbon dots (N/P CDs) for highly sensitive and selective MC-LR determination. The nanoscale N/P CDs were conveniently synthesized by one-step hydrothermal carbonization of adenosine 5′-triphosphate (ATP) in aqueous media. The fluorescence intensity of the N/P CDs was quenched in the presence of Fe<sup>3+</sup> due to the formation of Fe–O–P bonds between Fe<sup>3+</sup> and the phosphate groups of the N/P CDs. The resulting N/P CD-Fe<sup>3+</sup> system was sensitive to MC-LR, and its fluorescence intensity recovered dramatically and quickly since the MC-LR cavity competitively coordinated with Fe<sup>3+</sup>. Under optimized conditions, the proposed chemosensor exhibited a wide linear response for MC-LR in the range of 0.05–3 μg/L, with a detection limit down to 17.1 ng/L. Moreover, the chemosensor was successfully applied to accurately detect MC-LR in real water samples and achieved high recoveries in the range of 95.0–109.3%, with relative standard deviations within 1.8–4.7%. By relying on the benefits of fluorescent chemosensors, such as simple operation, low production cost, fast response time, selectivity, and sensitivity, the proposed sensing platform possesses promising applicability for MC-LR determination in complex environmental water samples.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsanm.1c00921?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsanm.1c00921</a>.Experimental materials and instrumentations; synthesis of N/P CDs; method of HPLC–MS determination; TEM, EDXS, FT-IR, and emission spectra of N/P CDs; stability of fluorescence intensity of the N/P CDs; fluorescence lifetime of the Fe<sup>3+</sup> on the N/P CDs; effects of various metal ions, pH values, concentrations of Fe<sup>3+</sup>, response times, and ionic strengths of experimental conditions (<a class="ext-link" href="/doi/suppl/10.1021/acsanm.1c00921/suppl_file/an1c00921_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,nanoscience & nanotechnology