Scatterer spacing based on Gabor atoms matched from harmonic ultrasound echoes to improve assessment of microwave‐induced thermal lesions

Xiuhua Zeng,Yufeng Zhang,Zhiyao Li,Jian Yang,Lian Gao,Junhua Zhang
DOI: https://doi.org/10.1002/mp.17384
IF: 4.506
2024-09-20
Medical Physics
Abstract:Background Microwave ablation (MWA) is a minimally invasive alternative for the treatment of unresectable liver tumors. To verify the effectiveness and safety of MWA, it is critical to measure the temperature variation and assess the regions of the microwave‐induced thermal lesions. Purpose Recent studies have indicated that the locations of optimally matched Gabor atoms (LOMGA) from ultrasound radiofrequency (RF) echo signals allow accurate and stable scatterer spacing estimation. Herein, a harmonic‐based LOMGA method is proposed to estimate the scatterer spacing for improving the assessment of microwave‐induced thermal lesions. Methods The mean scatterer spacing (MSS) is estimated via the LOMGA method incorporating the selection of concise atoms from separated second‐harmonic RF echo signals with the pulse‐inversion algorithm for thermal lesion evaluation. In vitro experiments, 10 fresh porcine liver samples were ablated at different time nodes during the ablation period, and 200 sets of second‐harmonic and fundamental RF echo signals were randomly selected from the regions of interest in the coagulated liver samples for MSS estimation. The means and standard deviations of the MSSs, as well as the linear regression for the mean MSSs, were calculated from fundamental and second‐harmonic signals for comparison and evaluation, the receiver operating characteristic (ROC) curves for the 200 sets of fundamental‐based and harmonic‐based MSS estimates from the 10 liver samples at five pairs of adjacent time nodes were calculated, and one‐way analysis of variance (ANOVA) tests were performed for the five pairs of adjacent time nodes. The fundamental and harmonic‐based p‐values in the ANOVA tests and the areas under the ROC curves (AUCs) were calculated to statistically analyze the differences in the MSSs between adjacent time nodes. Results The harmonic‐based increments in the intensity variation and coherent components were larger than the fundamental‐based increments with the increasing ablation time. The harmonic‐based MSSs from the 10 liver samples at five pairs of adjacent time nodes were found to be highly statistically significant (p
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?