B. Gopinath,S. Suresh,G. Jayabaskaran,M. Geetha,B. GopinathS. SureshG. JayabaskaranM. Geethaa Department of Electrical and Electronics Engineering,Christ the King Engineering College,Coimbatore,Indiab Department of Electrical and Electronics Engineering,Sri Eshwar College of Engineering,Coimbatore,Indiac Department of Electronics and Communication Engineering,Sri Eshwar College of Engineering,Coimbatore,India
DOI: https://doi.org/10.1080/00051144.2024.2329494
IF: 1.79
2024-03-27
Automatika
Abstract:In this paper, with the development of an intelligent power system idea, sustainable energy sources were increasingly deployed, including transmission and distribution systems networks. As a result, optimal use of cascaded H-bridge inverter topologies (MLIs) and power distribution operations is critical for long-term power generation. Traditionally, selective harmonics reduction models must be performed to achieve the optimal switching frequency of multilevel inverters. This research aims to determine the switching frequency for wind-incorporated multilevel inverters to reduce overall harmonic components used in grid applications. This research adds towards the best possible solution by employing multiple newly established adaptive optimization techniques: MNSGA-II and salp swarm. The well-known genetic algorithm and particle swarm optimization are used for the wind-tied multilevel inverters optimization issue. Seven-level, eleven-level, and fifteen-level MLIs were employed to reduce overall harmonic distortion. The reliability and convergence rate of simulated data with various modulation indices for seven-, eleven-, and fifteen-level MLIs are obtained and compared. Models are developed based on MATLAB Simulink and are used to validate quantitative measurements.
automation & control systems,engineering, electrical & electronic
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to reduce the total harmonic distortion in multi - level inverters with wind energy integration, in order to optimize their performance in grid applications. Specifically, the research aims to determine the switching frequency of multi - level inverters with wind energy integration to reduce the overall harmonic components. To achieve this goal, the research adopts a variety of newly - established adaptive optimization techniques, including the Modified Nondominated Sorting Genetic Algorithm (MNSGA - II) and the Salp Swarm Algorithm, as well as the traditional Genetic Algorithm (GA) and Particle Swarm Optimization (PSO). Through these methods, the research attempts to find the optimal switching frequency, thereby reducing the harmonic distortion generated during the operation of multi - level inverters and improving the reliability and efficiency of the system. In the research, seven - level, eleven - level and fifteen - level multi - level inverters (MLIs) are used to evaluate the effects of different optimization algorithms, and are verified through MATLAB Simulink modeling. The goal of the research is to reduce the total harmonic distortion of multi - level inverters by optimizing the switching frequency, thereby improving their application performance in wind energy systems.