Performance Degradation Modeling and Continuous Worktime Assessment of Ultrasonic Vibration Systems

Ruoyu Wang,Lei You,Xiaoping Hu
DOI: https://doi.org/10.3390/pr12030439
IF: 3.5
2024-02-23
Processes
Abstract:In order to assess the stable operating duration of an ultrasonic vibration system, a reliability-based analysis method for the stability of the ultrasonic vibration system is proposed. Firstly, the failure mechanisms of the ultrasonic vibration system are analyzed, and the resonant frequency and amplitude are selected as two degradation features of the system. Subsequently, accelerated degradation experiments under different force loads were conducted, and the degradation model of the ultrasonic vibration system was established by comparing experimental data with degradation, distribution, and acceleration models. Finally, Copula functions were introduced to connect the two degradation features, resonant frequency, and amplitude, and lifetime curves were plotted under the influence of univariate and bivariate degradation factors. Through the analysis of the lifetime curves, the conclusion is drawn that the decay of amplitude is the primary indicator of system lifetime, and it is predicted that the developed ultrasonic vibration system can operate continuously and stably for 26.69 h. This research is of great significance for enhancing the reliability and lifespan management of ultrasonic vibration systems.
engineering, chemical
What problem does this paper attempt to address?
The paper primarily studies the performance degradation of ultrasonic vibration systems and proposes a method for evaluating continuous stable working time. Specifically, the paper attempts to address the following core issues: 1. **Proposal of Reliability Analysis Method**: To assess the stable operating time of the ultrasonic vibration system, the authors propose a reliability-based analysis method. 2. **Selection of Degradation Characteristics**: By analyzing the failure mechanisms of the ultrasonic vibration system, resonance frequency drift and amplitude attenuation were selected as the two key degradation characteristics of the system. 3. **Design and Implementation of Accelerated Degradation Experiments**: Accelerated degradation experiments were conducted under different force load conditions to obtain degradation data and establish a degradation model for the ultrasonic vibration system. 4. **Establishment of Degradation Model**: By comparing experimental data, a suitable mathematical model was chosen to describe the degradation process of the ultrasonic vibration system. 5. **Analysis of the Impact of Bivariate Degradation Factors**: The Copula function was introduced to connect the two degradation characteristics, resonance frequency and amplitude, and the impact of univariate and bivariate degradation factors on the system's life curve was explored. 6. **System Life Prediction**: By analyzing the life curve, it was concluded that amplitude attenuation is the main indicator determining the system's life, and it was predicted that the developed ultrasonic vibration system can operate continuously and stably for 26.69 hours. This research is of great significance for improving the reliability and life management of ultrasonic vibration systems.