Theoretical performance study on R600/R170 auto-cascade refrigeration cycle with mechanical pre-cooling

Yongning He,Wenliang Cao,Su’ao Wang,Ke Xu,Xiangjie Kang,Yeqiang Zhang,Linfen Xing,Xuehong Wu
DOI: https://doi.org/10.1177/09544089241283617
2024-10-16
Proceedings of the Institution of Mechanical Engineers Part E Journal of Process Mechanical Engineering
Abstract:Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering, Ahead of Print. A mechanical pre-cooling auto-cascade refrigeration (PACR) system was proposed, R600a single-stage vapor compression system was used to provide pre-cooling for R600/R170 auto-cascade refrigeration (ACR) system. Performance of PACR system under different operating conditions was discussed. The result showed that maintaining a constant outlet temperature of 30°C for the condenser and −45°C for the evaporator in a PACR system resulted in an optimal intermediate temperature that maximized coefficient of cooling performance (COP). At this time, the optimal intermediate temperature of R600/R170 was 0°C, the COP maximum value (COPmax) was 0.693 and exergy efficiency (ηEx) was 20.9%. And as the evaporator outlet temperature decreases to −70°C, the optimal intermediate temperature decreases to −10°C. The cooling capacity (Qe) of the low-temperature grade circulating refrigerant in the PACR system using R600/R170 at different evaporation temperatures was increased by 86.3%–108% compared to that of R134a/R23. COPmax was increased by 7.1% compared to that of R134a/R23 at the evaporator outlet temperature of −60°C.
engineering, mechanical
What problem does this paper attempt to address?