Minimum perceptual time (MPT). Repeatability and reproducibility of variables applied to "sports vision"

Antonio Ríder-Vázquez,Margarita Vega-Holm,María Carmen Sánchez-González,Estanislao Gutiérrez-Sánchez
DOI: https://doi.org/10.1007/s00417-024-06684-7
2024-11-13
Graefe s Archive for Clinical and Experimental Ophthalmology
Abstract:"Minimum Perceptual Time" (MPT) is the ability to take the most visual information in the least time. The purpose of the study was to assess intraobserver and interobserver repeatability of a MPT measurement method by using COI-SV® software and to analyze the possible influence of age and sex. MPT was measured in 79 participants by using COI-SV® software. Visual acuity was 20/80 (2.50 m) and numbers were gradually increasing in quantity and decreasing in exposure time. The most quantity of numbers and the least time was written down. To assess intraobserver and interobserver repeatability, a protocol based on repeating the test 4 times (2 intrasession and 2 intersessions with 2 examinators) was established. Comparison of means and Spearman correlation were performed to evaluate the influence of sex and age. It was investigated inter and intraexaminer variability using repeatability indices, as well as Bland-Altman analysis to define limits of agreement. A total of 79 participants were included (mean age 32.8 ± 11.95 years, range 19–64 years). Regarding sex, there were no significant differences between men and women (p = 0.080), whereas age and MPT had an inverse correlation (p = 0.01). Interexaminer and intraexaminer repeatability proved to be moderate to good in all methods. Bland-Altman showed difference between sessions was 0.259 ± 2.189 (-4.030 and + 4.549) and difference between examiners was − 0.519 ± 2.104 (-4.642 and + 3.604). MPT measurements with COI-SV® software evidenced moderate to good repeatability and observers` independent result, so it could be included in optometric examinations.
ophthalmology
What problem does this paper attempt to address?