Scintillation yield of liquid xenon at room temperature
K. Ueshima,K. Abe,T. Iida,M. Ikeda,K. Kobayashi,Y. Koshio,A. Minamino,M. Miura,S. Moriyama,M. Nakahata,Y. Nakajima,H. Ogawa,H. Sekiya,M. Shiozawa,Y. Suzuki,A. Takeda,Y. Takeuchi,M. Yamashita,K. Kaneyuki,T. Doke,Y. Ebizuka,J. Kikuchi,A. Ota,S. Suzuki,T. Takahashi,H. Hagiwara,T. Kamei,K. Miyamoto,T. Nagase,S. Nakamura,Y. Ozaki,T. Sato,Y. Fukuda,T. Sato,K. Nishijima,M. Sakurai,T. Maruyama,D. Motoki,Y. Itow,H. Ohsumi,S. Tasaka,S.B. Kim,Y.D. Kim,J.I. Lee,S.H. Moon,The XMASS Collaboration
DOI: https://doi.org/10.1016/j.nima.2008.06.017
2008-09-01
Abstract:The intensity of scintillation light emission from liquid xenon at room temperature was measured. The scintillation light yield at 1∘C was measured to be 0.64±0.02 (stat.) ±0.06 (sys.) of that at -100∘C. Using the reported light yield at -100∘C (46photons/keV), the measured light yield at 1∘C corresponds to 29photons/keV. This result shows that liquid xenon scintillator provides high light yield even at room temperature.