Investigating Radon Concentrations in the Cango Cave, South Africa

Jacques Bezuidenhout,Rikus le Roux
DOI: https://doi.org/10.3390/atmos15091133
IF: 3.11
2024-09-19
Atmosphere
Abstract:Radon concentrations in the tourist part of the Cango cave were measured using 25 strategically placed electret ion chambers. Airflow rates were also measured and found to be less than 1 m/s throughout the cave. An IDW interpolated radon concentration overlay was constructed using QGIS and overlayed on maps of the cave. The maximum radon concentration of 2625 Bq/m3 was measured in the Grand Hall, located in the central part of the cave following a narrow passage. The initial part of the cave near the entrance exhibited normal cave breathing characteristics, with radon concentrations of less than 300 Bq/m3. The deepest section of the cave, however, demonstrated an unexpected decrease in radon levels, temperature, and humidity. The average radon concentration in the Cango cave, measured at 1265 Bq/m3, is relatively low compared to other caves worldwide that need mitigation measures according to the International Commission on Radiological Protection (ICRP).
environmental sciences,meteorology & atmospheric sciences
What problem does this paper attempt to address?