Building instructions for a ferromagnetic axion haloscope

Nicolò Crescini
DOI: https://doi.org/10.1140/epjp/s13360-022-02533-w
2022-03-01
The European Physical Journal Plus
Abstract:<p class="a-plus-plus">A ferromagnetic haloscope is a rf spin magnetometer used for searching dark matter in the form of axions. A magnetic material is monitored searching for anomalous magnetization oscillations which can be induced by dark matter axions. To properly devise such instrument, one first needs to understand the features of the searched-for signal, namely the effective rf field of dark matter axions <span class="a-plus-plus inline-equation id-i-eq1"><span class="a-plus-plus equation-source format-t-e-x"><span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="2.818ex" height="2.509ex" style="vertical-align: -0.671ex;" viewBox="0 -791.3 1213.4 1080.4" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-42" x="0" y="0"></use> <use transform="scale(0.707)" xlink:href="#MJMAIN-61" x="1074" y="-213"></use></g></svg></span></span></span> acting on electronic spins. Once the properties of <span class="a-plus-plus inline-equation id-i-eq2"><span class="a-plus-plus equation-source format-t-e-x"><span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="2.818ex" height="2.509ex" style="vertical-align: -0.671ex;" viewBox="0 -791.3 1213.4 1080.4" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-42" x="0" y="0"></use> <use transform="scale(0.707)" xlink:href="#MJMAIN-61" x="1074" y="-213"></use></g></svg></span></span></span> are defined, the design and test of the apparatus may start. The optimal sample is a narrow linewidth and high spin-density material such as yttrium-iron garnet, coupled to a microwave cavity with almost matched linewidth to collect the signal. The power in the resonator is collected with an antenna and amplified with a Josephson parametric amplifier, a quantum-limited device which, however, adds most of the setup noise. The signal is further amplified with low-noise HEMT and down-converted for storage with an heterodyne receiver. This work describes how to build such apparatus, with all the experimental details, the main issues one might face, and some solutions.</p><svg xmlns="http://www.w3.org/2000/svg" style="display: none;"><defs id="MathJax_SVG_glyphs"><path stroke-width="1" id="MJMATHI-42" d="M231 637Q204 637 199 638T194 649Q194 676 205 682Q206 683 335 683Q594 683 608 681Q671 671 713 636T756 544Q756 480 698 429T565 360L555 357Q619 348 660 311T702 219Q702 146 630 78T453 1Q446 0 242 0Q42 0 39 2Q35 5 35 10Q35 17 37 24Q42 43 47 45Q51 46 62 46H68Q95 46 128 49Q142 52 147 61Q150 65 219 339T288 628Q288 635 231 637ZM649 544Q649 574 634 600T585 634Q578 636 493 637Q473 637 451 637T416 636H403Q388 635 384 626Q382 622 352 506Q352 503 351 500L320 374H401Q482 374 494 376Q554 386 601 434T649 544ZM595 229Q595 273 572 302T512 336Q506 337 429 337Q311 337 310 336Q310 334 293 263T258 122L240 52Q240 48 252 48T333 46Q422 46 429 47Q491 54 543 105T595 229Z"></path><path stroke-width="1" id="MJMAIN-61" d="M137 305T115 305T78 320T63 359Q63 394 97 421T218 448Q291 448 336 416T396 340Q401 326 401 309T402 194V124Q402 76 407 58T428 40Q443 40 448 56T453 109V145H493V106Q492 66 490 59Q481 29 455 12T400 -6T353 12T329 54V58L327 55Q325 52 322 49T314 40T302 29T287 17T269 6T247 -2T221 -8T190 -11Q130 -11 82 20T34 107Q34 128 41 147T68 188T116 225T194 253T304 268H318V290Q318 324 312 340Q290 411 215 411Q197 411 181 410T156 406T148 403Q170 388 170 359Q170 334 154 320ZM126 106Q126 75 150 51T209 26Q247 26 276 49T315 109Q317 116 318 175Q318 233 317 233Q309 233 296 232T251 223T193 203T147 166T126 106Z"></path></defs></svg>
What problem does this paper attempt to address?