SARS-CoV-2 inactivation by supercritical carbon dioxide coupled with hydrogen peroxide

Riccardo Zulli,Claudia Del Vecchio,Pietro Andrigo,Valeria Conciatori,Fabio Santi,Alessandro Zambon,Enrico Lavezzo,Sara Spilimbergo
DOI: https://doi.org/10.1016/j.supflu.2024.106272
IF: 3.9
2024-04-10
The Journal of Supercritical Fluids
Abstract:The recent COVID-19 pandemic has underscored the need for innovative decontamination techniques capable of treating sensitive materials potentially contaminated. Combining supercritical carbon dioxide (scCO 2 ) with sterilant agents has shown promise in this regard. This study aimed at testing scCO 2 as a virus inactivation method for biomedical materials contaminated with the Severe Acute Respiratory Syndrome Corona Virus 2 (SARS-CoV-2). The virus was inoculated on a stainless-steel carrier and treated at 45°C and 8 MPa. No inactivation was detected when only scCO 2 was used, even after long treatment times (60 min). The addition of 50 ppm of H 2 O 2 to the process allowed the inactivation of more than 5 Log PFU (Plaque Forming Unit) of the virus by only pressurising and depressurising the vessel, while a 20-min process is needed by only using H 2 O 2 . Overall, the study demonstrates a synergistic effect when H 2 O 2 is added to the scCO 2 process for the inactivation of SARS-CoV-2.