Abstract:Aggregation-induced emission (AIE) active Pdots are attractive nanomaterials applied in electrochemiluminescence (ECL) fields, while the irreversible redox reaction of these Pdots is a prevailing problem, resulting in instability of ECL emission. Herein, we first designed and synthesized an AIE-active Pdot with reversible redox property, which contains a tetraphenylethene derivate and benzothiadiazole (BT) to achieve stable ECL emission. BT has a good rigid structure with excellent electrochemical behaviors, which is beneficial for avoiding the destruction of the conjugated structure as much as possible during the preparation of Pdots, thus maintaining good redox property. The tetraphenylethene derivate, as a typical AIE-active moiety, provides a channel for highly efficient luminescence in the aggregated states. The Pdots exhibited reversible and quasi-reversible electrochemical behaviors during cathodic and anodic scanning, respectively. The stable annihilation, reductive–oxidative, and oxidative–reductive ECL signals were observed. Subsequently, we constructed an ultrasensitive ECL biosensor based on the oxidative–reductive ECL mode for the detection of miRNA-21 with a detection limit of 32 aM. This work provides some inspiration for the future design of ECL materials featuring AIE-active property and stable ECL emission.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.analchem.1c00947?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.analchem.1c00947</a>.Materials, reagents, apparatus, ECL spectrum measurement, experiment of ECL imaging, <sup>1</sup>H NMR characterization, and absorbance spectra of the polymer; absorbance and PL lifetime spectra of Pdots; reductive–oxidative ECL of Pdots with K<sub>2</sub>S<sub>2</sub>O<sub>8</sub>; corresponding CV and stability of ECL emission; CV of TPrA; polyacrylamide gel electrophoresis image; optimization of the kind and concentration of coreactants; CV and EIS profiles of the stepwise fabrications of the ECL sensor; sequences of DNA and miRNA used in this work; summarization of the photophysical characterization data for Pdots; and comparison of the ECL efficiency of different nanomaterials and analytical performance comparison of different methods for detection of miRNA-21 (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.1c00947/suppl_file/ac1c00947_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, analytical