Online polymer monolith microextraction with in-situ derivatization for sensitive detection of endogenous brassinosteroids by LC-MS

Xiang-Yu Wang,Cai-Feng Xiong,Tian-Tian Ye,Jun Ding,Yu-Qi Feng
DOI: https://doi.org/10.1016/j.microc.2020.105061
IF: 5.304
2020-11-01
Microchemical Journal
Abstract:<p>An automatic and sensitive method which integrated polymer monolith microextraction and in-situ derivatization with liquid chromatography-mass spectrometry (PMME-ISD-LC-MS) was proposed for the quantification of endogenous brassinosteroids (BRs) in plant samples. In the described method, the anionic HIILIC monolithic column was modified with 2-methyl-4-phenylaminomethylphenylboronic acid (2-methyl-4-PAMBA) through ion exchange interaction and then used as a boronate affinity media to selectively capture, purify and derivatize BRs in crude extract through the reaction of the boronic acid group of 2-methyl-4-PAMBA and <em>cis</em>-diol on BRs. The BR derivatives were easily eluted by destroying the ion exchange interactions using the acidic eluting solvent, and then analyzed by LC-MS. The whole extraction and LC-MS analysis processes were automatically controlled which could be completed within 50 min. Under the optimized conditions, good linearities were obtained for six BRs with the correlation coefficients (R) ranging from 0.9953 to 0.9998. The limits of detection (LODs, S/N = 3) ranged from 0.10 to 1.29 pg mL<sup>−1</sup>. The recoveries were between 82.3% and 119.1% with the relative standard deviations (RSDs) ranging from 2.2% to 18.3%. Finally, the proposed method was applied for the quantification of endogenous BRs in various plant samples including different <em>Oryza sativa</em> L. cv. tissues (1.0 mg, fresh weight (FW)), <em>Phaseolus vulgaris</em> L. (1.0 mg FW), <em>Vigna unguiculata</em> (1.0 mg FW), <em>Arabidopsis thaliana</em> flower (1.3 mg FW).</p>
chemistry, analytical
What problem does this paper attempt to address?
This paper aims to solve several key problems in the detection of endogenous brassinosteroids (BRs) in plants: 1. **Improve detection sensitivity**: The content of BRs in plants is extremely low (0.01 - 0.1 ng g\(^{-1}\) fresh weight), and it lacks photo - sensitive, electro - sensitive or easily ionized groups, which makes direct detection very difficult. The paper proposes a highly sensitive method, which realizes the efficient detection of BRs by combining on - line polymer monomer micro - extraction and in - situ derivatization with liquid chromatography - mass spectrometry (PMME - ISD - LC - MS) technology. 2. **Simplify sample pretreatment**: Traditional BRs detection methods usually require multi - step manual sample pretreatment, which is not only time - consuming and labor - intensive, but also may lead to low recovery rates and measurement errors. The paper has developed a fully automated on - line analysis system, which can complete the entire extraction and LC - MS analysis process within 50 minutes, greatly simplifying the sample pretreatment steps. 3. **Improve selectivity and purification efficiency**: The detection of BRs requires highly selective adsorption materials to remove interfering substances in complex matrices. 2 - methyl - 4 - phenylaminomethylphenylboronic acid (2 - methyl - 4 - PAMBA) used in the paper is immobilized on an anion - hydrophilic interaction chromatography (HIILIC) monomer column by ion - exchange, and can specifically capture, purify and derivatize BRs, thus improving selectivity and purification efficiency. 4. **Applicable to various plant samples**: The paper verifies the applicability of this method in different plant samples, including different tissues of rice (panicle, leaf, stem, root), kidney bean, cowpea and Arabidopsis thaliana flower. The results show that this method can quantitatively detect a variety of BRs in 1.0 mg to 1.3 mg of fresh plant tissues, and has broad application potential. In summary, the main objective of this paper is to develop a rapid, sensitive and fully automatic on - line analysis method for the efficient detection of endogenous BRs in plant samples, solving the problems of low sensitivity, cumbersome sample pretreatment and low selectivity in traditional methods.