Soil CO 2 fluxes measured in the Acoculco Geothermal System, Mexico: Baseline emissions from a long-term prospection programme

Daniel Pérez-Zárate,Edgar Santoyo,Mariana Patricia Jácome-Paz,Mirna Guevara,Fernando Guerero,David Yáñez-Dávila,Gustavo Santos-Raga
DOI: https://doi.org/10.1016/j.chemer.2024.126112
2024-03-17
Chemie der Erde
Abstract:The Acoculco Caldera Complex is considered a promissory hidden high-temperature geothermal system in Mexico. To support the geothermal prospection of this anomalous area, a comprehensive programme of soil CO 2 flux measurements was performed. A long-term measurement programme was conducted to determine the baseline of natural soil CO 2 effluxes. Significant efforts were devoted both to measuring the CO 2 fluxes between 2015 and 2022 and interpreting their origin. A comprehensive database was created using statistical and geostatistical methods to study the geochemical features of these soil CO 2 fluxes. This study allows the spatial distribution and the total CO 2 efflux to be quantified. Eighteen soil gas surveys of CO 2 were carried out by using the accumulation chamber method. >1200 diffuse CO 2 fluxes were measured in six different areas of the Acoculco Caldera. Two areas (Los Azufres and Alcaparrosa) exhibited cold degassing sites, acid-sulphate springs, and gas bubbling in surface water bodies. In contrast, other areas were related to grassland and pine forest sites. Using the graphical statistical approach (GSA) and the sequential Gaussian simulation (SGS), three degassing groups were identified. These soil CO 2 fluxes were classified as high (group A), intermediate (group B), and low gas emissions (group C). The soil CO 2 fluxes ranged from 1 to 26,000 g m −2 d −1 , whereas lower fluxes <29 g m −2 d −1 were determined as the degassing baseline. A total CO 2 flux of 492 t d −1 km −1 was estimated for the Acoculco Caldera using an integrated SGS-GSA approach, where the highest total soil CO 2 fluxes were obtained for Alcaparrosa (299 t d −1 km −2 ) compared with Los Azufres (164 t d −1 km −2 ), and Surroundings (29 t d −1 km −2 ). Such results agree well with those values measured in other worldwide volcanic and active geothermal ecosystems. The range of CO 2 isotopic composition values from −28.83 ‰ to −3.11 ‰, together with their statistical distribution, suggests multiple CO 2 production sources feeding soil degassing. The combined interpretation of flux and isotopic data allowed us to identify two distinct gas sources: hydrothermal and biogenic. The composition in δ 13 C CO2 with the highest soil CO 2 effluxes indicates a magmatic source with values of δ 13 C CO2 between −5.36 ‰ and −3.11 ‰. The CO 2 from biogenic sources and low CO 2 effluxes is characterised by values of δ 13 C CO2 between −28.83 ‰ to −15.77 ‰, both in the range of the typical values for biological CO 2 soil degassing. The present study highlights the importance of using soil CO 2 monitoring to determine baseline emissions at the early exploration stage of geothermal systems.
geosciences, multidisciplinary,geography, physical
What problem does this paper attempt to address?