Effects of CO2 Changes on Hyperspectral Infrared Radiances and Its Implications on Atmospheric Temperature Profile Retrieval and Data Assimilation in NWP

Di Di,Yunheng Xue,Jun Li,Wenguang Bai,Peng Zhang
DOI: https://doi.org/10.3390/rs12152401
IF: 5
2020-07-27
Remote Sensing
Abstract:Although atmospheric CO2 is a trace gas, it has seasonal variations and has increased over the last decade. Its seasonal variation and increase have substantial radiative effects on hyperspectral infrared (IR) radiance calculations in both longwave (LW) and shortwave (SW) CO2 absorption spectral regions that are widely used for weather and climate applications. The effects depend on the spectral coverage and spectral resolution. The radiative effect caused by the increase of CO2 has been calculated to be greater than 0.5 K within 5 years, whereas a radiative effect of 0.1–0.5 K is introduced by the seasonal variation in some CO2 absorption spectral regions. It is important to take into account the increasing trend and seasonal variation of CO2 in retrieving the atmospheric temperature profile from hyperspectral IR radiances and in the radiance assimilation in numerical weather prediction (NWP) models. The simulation further indicates that it is very difficult to separate atmospheric temperature and CO2 information from hyperspectral IR sounder radiances because the atmospheric temperature signal is much stronger than that of CO2 in the CO2 absorption IR spectral regions.
environmental sciences,imaging science & photographic technology,remote sensing,geosciences, multidisciplinary
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to explore the impact of carbon dioxide (CO₂) concentration changes on hyperspectral infrared radiation measurement, and how these impacts further affect the retrieval of atmospheric temperature profiles and radiative assimilation in numerical weather prediction (NWP) models. Specifically, the paper focuses on the following aspects: 1. **Impact of CO₂ changes on hyperspectral infrared radiation simulation**: - By studying how changes in CO₂ concentration (including long - term trends and seasonal changes) affect the simulation results of hyperspectral infrared radiation. - The paper points out that changes in CO₂ concentration will produce significant radiation effects in some specific bands (such as 15 µm, 5.2 µm, 4.8 µm and 4.5 µm), especially within the CO₂ absorption band. 2. **How to consider CO₂ changes in atmospheric temperature profile retrieval and data assimilation**: - Research shows that changes in CO₂ concentration will affect the accuracy of retrieving atmospheric temperature profiles from hyperspectral infrared radiation measurements. For example, an increase of 5 ppmv in CO₂ concentration may lead to a radiation effect of 0.2 K, and an increase of 10 ppmv may make the radiation effect exceed 0.5 K. - Seasonal changes (about 5 - 9 ppmv) may also lead to a radiation effect of 0.1 - 0.5 K, which will bring challenges to the bias correction (BC) process and temperature profile retrieval. 3. **Possibility of separating CO₂ and atmospheric temperature information from hyperspectral infrared radiation measurements**: - The paper explores whether it is possible to simultaneously retrieve CO₂ content or profiles from hyperspectral infrared radiation measurements, and evaluates the required spectral resolution and signal - to - noise ratio. - The results show that due to the strong coupling between the CO₂ absorption signal and the atmospheric temperature signal, it is very difficult to separate these two kinds of information, especially within the CO₂ absorption band. ### Formula representation In order to describe the radiation effect more accurately, the paper uses the brightness temperature difference (BTD) to quantify the impact of CO₂ changes. For example: \[ \text{BTD} = T_{\text{new}} - T_{\text{ref}} \] where \(T_{\text{new}}\) is the brightness temperature after the change of CO₂ concentration, and \(T_{\text{ref}}\) is the brightness temperature in the reference state. In addition, the interferogram signal difference (ISD) is also used to further analyze the radiation effect: \[ \text{ISD} = I_{\text{new}} - I_{\text{ref}} \] where \(I_{\text{new}}\) is the interferogram signal after the change of CO₂ concentration, and \(I_{\text{ref}}\) is the interferogram signal in the reference state. ### Summary This paper aims to reveal the impact of CO₂ concentration changes on hyperspectral infrared radiation measurement through detailed simulation experiments and data analysis, and provide a scientific basis for improving the retrieval of atmospheric temperature profiles and numerical weather prediction models.