Journal of Bone and Mineral Research
Abstract:Abstract Data on bone microarchitecture in osteogenesis imperfecta (OI) are scarce. The aim of this cross-sectional study was to assess bone microarchitecture and strength in a large cohort of adults with OI using high-resolution peripheral quantitative CT (HR-pQCT) and to evaluate challenges of using HR-pQCT in this cohort. Second-generation HR-pQCT scans were obtained at the distal radius and tibia in 118 men and women with Sillence OI type I, III, or IV using an extremity-length dependent scan protocol. In total, 102 radius and 105 tibia scans of sufficient quality could be obtained, of which 11 radius scans (11%) and 14 tibia scans (13%) had a deviated axial scan angle as compared to axial angle data of 13 young women. In the scans without a deviated axial angle and compared to normative HR-pQCT data, Z-scores at the radius for trabecular BMD, number, and separation were -1.6 ± 1.3, -2.5 ± 1.4, and -2.7 (IQR: 2.7), respectively. They were -1.4 ± 1.5 and -1.1 ± 1.2 for stiffness and failure load and between ±1 for trabecular thickness and cortical bone parameters. Z-scores were significantly lower for total and trabecular BMD, stiffness, failure load, and cortical area and thickness at the tibia. Additionally, local microarchitectural inhomogeneities were observed; most pronounced being trabecular void volumes. In the scans with a deviated axial angle, the proportion of Z-scores <-4 or > 4 was significantly higher for trabecular BMD and separation (radius) or most total and trabecular bone parameters (tibia). To conclude, especially trabecular bone microarchitecture and bone strength were impaired in adults with OI. HR-pQCT may be used without challenges in most adults with OI, but approximately 12% of the scans may have a deviated axial angle in OI due to bone deformities or scan positioning limitations. Furthermore, standard HR-pQCT parameters may not always be reliable due to microarchitectural inhomogeneities nor fully reflect all inhomogeneities.
endocrinology & metabolism
What problem does this paper attempt to address?
This paper aims to evaluate the bone microstructure and bone strength in adult patients with Osteogenesis Imperfecta (OI) and compare them with the data of the normal population. Specifically, the researchers used High - Resolution Peripheral Quantitative Computed Tomography (HR - pQCT) technology to scan the distal radius and distal tibia of 118 adult patients with Osteogenesis Imperfecta (Sillence type I, III or IV). In addition, the study also evaluated the possible challenges of using HR - pQCT technology in this population, especially the problem of scan area deviation due to short limbs and skeletal deformities. ### Research Background Osteogenesis Imperfecta is a rare and highly heterogeneous connective tissue disease, mainly caused by gene mutations related to the structure or processing of type I procollagen, which affects the quantity or quality of type I collagen. This disease leads to fragile bones and an increased risk of fractures. Although Dual - Energy X - ray Absorptiometry (DXA) can provide bone density measurements, these data may be affected by bone size and deformities. Therefore, there are relatively few studies on bone microstructure defects. ### Research Objectives 1. **Evaluate bone microstructure and bone strength**: Evaluate the bone microstructure and bone strength in adult patients with Osteogenesis Imperfecta by using HR - pQCT technology and compare them with the data of the normal population. 2. **Evaluate the challenges of HR - pQCT technology**: Explore the possible challenges of using HR - pQCT technology in adult patients with Osteogenesis Imperfecta, especially the problem of scan area deviation due to short limbs and skeletal deformities. ### Main Findings - **Impaired bone microstructure**: Compared with the normal population, the number of trabeculae in patients with Osteogenesis Imperfecta decreased, and the trabecular separation increased. In particular, the trabecular bone density, trabecular volume fraction and trabecular number at the distal radius were significantly reduced. - **Decreased bone strength**: The bone strength (such as stiffness and failure load) of patients was also significantly lower than that of the normal population. - **Scan area deviation**: Approximately 12% of the scans had axial angle deviation, which may be caused by skeletal deformities or scan positioning limitations. These deviations may affect the accuracy of HR - pQCT parameters. - **Microstructural inhomogeneity**: Local microstructural inhomogeneity was observed, especially a significant increase in trabecular void volume. ### Conclusions The bone microstructure and bone strength in patients with Osteogenesis Imperfecta are significantly impaired, especially in terms of trabeculae. Although the HR - pQCT technology can be used normally in most patients with Osteogenesis Imperfecta, due to skeletal deformities or scan positioning limitations, approximately 12% of the scans may have axial angle deviation. In addition, the standard HR - pQCT parameters may not fully reflect all microstructural inhomogeneities. ### Keywords - Osteogenesis Imperfecta - High - Resolution Peripheral Quantitative Computed Tomography - Bone Microstructure - Bone Strength - Normative Comparison ### Notes - **HR - pQCT**: High - Resolution Peripheral Quantitative Computed Tomography, used for non - invasively evaluating bone microstructure. - **Z - score**: Standardized score, used to compare the differences between individuals and the normal population of the same age and gender. A negative value indicates below the normal level, and a positive value indicates above the normal level.