Ultrasonic monitoring of lithium-ion batteries with in-situ self-temperature correction

Ali Soleimani Borujerdi,Congrui Jin,Jinying Zhu
DOI: https://doi.org/10.1016/j.jpowsour.2024.234103
IF: 9.2
2024-01-28
Journal of Power Sources
Abstract:This paper presents an ultrasonic technique to monitor the state of charge (SOC) of lithium-ion batteries by establishing a relationship between the ultrasonic parameters and SOC. Three lithium-ion batteries (800, 1050, and 3650 mAh) were tested at three C-rates (0.1C, 0.5C, and 1C) for six charge/discharge cycles. Ultrasonic amplitude and time of flight (TOF) shift were measured along with the voltage and current during cycling tests. Because the TOF shift is affected by the temperature change, an in-situ temperature-correction method was proposed. We established the correlation between TOF shift and temperature for different SOCs based on the TOF and temperature data collected during the battery cycling test, instead of performing separate experiments in a chamber to obtain the TOF vs. temperature relationship. After the temperature correction, the TOF shift showed a good correlation with the SOC, which was unaffected by the C-rate. In addition, the hysteresis area in the TOF-SOC relationship decreased significantly by up to 67% which shows that the temperature correction is indispensable to the ultrasonic monitoring.
energy & fuels,materials science, multidisciplinary,electrochemistry,chemistry, physical
What problem does this paper attempt to address?