A Cable-Based Haptic Interface with a Reconfigurable Structure

Bastien Poitrimol,Hiroshi Igarashi
DOI: https://doi.org/10.1115/1.4065318
2024-04-15
Journal of Mechanisms and Robotics
Abstract:Abstract Cable robots have been used as haptic interfaces for several decades now, with the most notable examples being the SPIDAR and its numerous iterations throughout the years, as well as the more recent IPAnema 3 Mini manufactured by Fraunhofer IPA. However, these robots still have drawbacks, particularly their high number of cables required to maintain a high workspace-to-installation-space ratio. Using a hybrid-structure cable robot (HSCR) could prevent some collisions that occur between the cables and the user's body. More specifically, some applications requiring multimodal feedback could benefit from the flexibility that a reduced number of cables offers. Therefore, this paper presents a novel SPIDAR-like VSCR and its sensor-less force control method based on motor current. The purpose of this work is to clarify the advantages that a variable structure can provide for haptic interaction. In this regard, experimental results regarding the device's workspace and its force feedback capabilities are presented. Additionally, since real-time high-frequency updates are required for haptic display, we provide additional data regarding the control algorithm's runtime. Lastly, another experiment was conducted to study changes in user performance when using both the variable and the usual cable configuration. The results showed that feedback accuracy is maintained, and there are no drawbacks to using hybrid configurations.
robotics,engineering, mechanical
What problem does this paper attempt to address?
The problems that this paper attempts to solve are several key issues existing in the current cable - based haptic interfaces when providing force feedback: 1. **High number of cables**: Traditional cable - based robots (such as SPIDAR and its variants) require a large number of cables to maintain a high ratio of workspace to installation space, which leads to poor workspace efficiency, increases the potential interference between cables and the user's body, limits the user's degrees of freedom, and may cause management problems when integrating other devices in multi - modal haptic applications. 2. **Lack of diverse feedback**: Existing cable - based haptic devices usually display the virtual environment through a simple screen, lacking diverse haptic feedback and unable to meet the complex human - machine interaction requirements. 3. **Structural fixity**: Most existing haptic interfaces do not support the rotation of the end - effector, which makes the control scheme and the design of the end - effector relatively simple, but also limits the possibilities of the interface. To solve these problems, the paper proposes a new type of hybrid - structure cable robot (HSCR). This robot has a reconfigurable structure, which can reduce the number of required cables, improve the utilization efficiency of the workspace, and provide more flexible multi - modal haptic feedback. Specifically, the paper introduces this new SPIDAR - style HSCR and its sensorless force control method based on motor current, aiming to verify the advantages of the variable structure in haptic interaction. Through the experimental results, the paper shows the workspace and force - feedback capabilities of this device and provides data on the running time of the control algorithm to ensure the real - time performance of the device. In addition, an experiment was also carried out to study the influence of using variable and regular cable configurations on user performance. The results show that the feedback accuracy is maintained and there are no obvious disadvantages in using the hybrid configuration.