Validation of the Fully Automated Idylla System for Microsatellite Instability Detection in Chinese Colorectal Cancer Patients.
Qian Wang,Jing Zhang,Chengli Yu,Longlong Bao,Xu Cai,Wenhua Jiang,Dan Huang,Xiaoli Zhu,Qianming Bai,Xiaoyan Zhou
DOI: https://doi.org/10.19401/j.cnki.1007-3639.2022.11.006
IF: 45.3
2020-01-01
Journal of Clinical Oncology
Abstract:e13644 Background: Mismatch repair (MMR)/microsatellite instability (MSI) testing is recommended by NCCN Guidelines to screen for Lynch Syndrome as well as to predict response to immune checkpoint inhibitors in solid tumors. Conventional methods for MSI detection, immunohistochemistry (IHC) and polymerase chain reaction (PCR), often require non-tumor controls as well as a long turnaround time. The Idylla system, in contrast, is a fully automated quantitative PCR unit with a turnaround time of 2.5 hours. Neither does it require normal tissue or special training to operate. The Idylla MSI Test has been CE-marked for its reliability among Caucasian colorectal cancer (CRC) patients, but has never been validated in Chinese CRC population. Methods: Formalin-fixed paraffin-embedded (FFPE) tissue samples were collected from 87 CRC patients and were subjected to MMR/MSI detection using IHC, PCR and the Idylla test separately. The Idylla MSI Test incorporates 7 novel MSI loci, ACVR2A, BTBD7, DIDO1, MRE11, RYR3, SEC31A, and SULF2. The sensitivity and specificity of the Idylla system were evaluated in comparison with PCR and IHC. Results: Of the 87 patients enrolled, both IHC and PCR identified 55 to be MMR-deficient (dMMR)/MSI-high (MSI-H), of which 4 were MSS using Idylla, and 32 to be MMR-proficient (pMMR)/microsatellite stable (MSS) where Idylla classified one as MSI-H, yielding a sensitivity of 92.7%, a specificity of 96.9% and an overall concordance of 94.3%. Re-examination of the 5 discordant cases (4 false negatives and 1 false positive) using DNA extractions instead of tissue slices on the Idylla platform displayed 100% consistency with IHC/PCR. Confirmation on the Idylla system using recut sections corrected 3 false negatives and 1 false positive, with all tumor contents of ≥20%, 1 Idylla-defined MSS sample with 5% tumor content remained discordant even after sample enrichment. Conclusions: The Idylla system provides a fast, reliable, and user-friendly solution to MSI detection in Chinese CRC patients with high sensitivity and specificity. Upfront assessment of tissue sample quality ( i.e. tumor area and tumor cell fraction) is critical for the accuracy of this test. The reproducibility of the assay warrants further investigation.