An equivalent modeling method of the umbilical hydraulic characteristics and the simulator for the umbilical

Shoubo Shang,Peng Jia,Xiangyu Wang,Feihong Yun,Jing Wen,Xin Wang,Liquan Wang
DOI: https://doi.org/10.1016/j.oceaneng.2024.117230
IF: 5
2024-02-27
Ocean Engineering
Abstract:This paper proposed an equivalent model for the hydraulic characteristics of the umbilical with hydraulic resistance, hydraulic inductance and hydraulic capacitance. Based on the model, an umbilical simulator is designed for subsea control model tests. The simulation of the pressurizing and relieving, and production master valve opening and closing are conducted through SimulationX. The simulator's performances are verified through the sea trials. In the umbilical simulator, the slender pipe, the accumulator, and the hydraulic motor and flywheel can be employed as the hydraulic resistance, hydraulic capacitance and inductance, respectively. Their sequence affects the simulator's performances and the best sequence is capacitance-inductance-resistance. The simulation results of the simulator and the umbilical are analyzed and compared. The pressurizing and relieving times of the umbilical are 529s and 192s, while that of the simulator are 572s and 165s. The opening and closing times of the umbilical are 4.4s and 8.3s, while that of the simulator are 4.8s and 8.2s. The sea trials show that the errors for the simulator of the pressurizing time, the production master valve opening and closing time are 11.12%, 11.62% and 7.89%, respectively.
engineering, civil, ocean, marine,oceanography
What problem does this paper attempt to address?