Test Study on the Resistance of Chloride ion Penetration of Recycled Aggregate Concrete

Liu Hui-qiang,D. Ting
Abstract:The corrosion of steel bar caused by the chloride ion eroding into the concrete is the main reason of durability descent and fracture of the concrete structure,and in the same way,the resistance of chloride ion penetration of recycled aggregate concrete is directly related to the safety and durability of the recycled aggregate concrete structure.Aiming at those,the contrast test of chloride ion penetrability of the recycled aggregate concrete and the natural aggregate concrete which were added in fly ash,granulated blast-furnace slag and high-rang water reducing agent was carried out by using the method of ASTM C1202.The test results indicate that the minimal admixtures,such as fly ash,granulated blast-furnace slag and so on,can effectively improve the chloride ion penetrability of the recycled aggregate concrete to some extent,and the resistance of chloride ion penetration of recycled aggregate concrete has been intensified with the growth of the concrete's strength and curing age.The test results also show that the resistance of chloride ion penetration of recycled aggregate concrete remains good,but the resistance of chloride ion penetration of recycled aggregate concrete is lower than that of the natural aggregate concrete.
Engineering,Materials Science,Environmental Science