Comparison of the spectral performance between two dual-source CT systems on low-energy virtual monoenergetic images: A phantom study

Joël Greffier,Sebastian Faby,Maxime Pastor,Julien Frandon,Julien Erath,Jean-Paul Beregi,Djamel Dabli
DOI: https://doi.org/10.1016/j.ejmp.2024.103429
IF: 3.119
2024-07-19
Physica Medica
Abstract:Highlights • With new DSCT, noise magnitude was slightly higher compared to the previous DSCT. • With new DSCT, detectability slightly lower compared to the previous DSCT. • New DSCT showed a finer noise texture compared to the previous DSCT. • New DSCT showed a sligthly higher spatial resolution compared to the previous DSCT. • For both DSCTs, the best detectability was found at 40 keV, whatever the dose level. Purpose To compare the spectral performance of two different DSCT (DSCT-Pulse and DSCT-Force) on virtual monoenergetic images (VMIs) at low energy levels. Methods An image quality phantom was scanned on the two DSCTs at three dose levels: 11/6/1.8 mGy. Level 3 of an advanced modeled iterative reconstruction algorithm was used. Noise power spectrum and task-based transfer function were computed on VMIs from 40 to 70 keV to assess noise magnitude and noise texture (f av ) and spatial resolution (f 50 ). A detectability index (d') was computed to assess the detection of one contrast-enhanced abdominal lesion as a function of the keV level used. Results For all dose levels and all energy levels, noise magnitude was significantly higher (p < 0.05) with DSCT-Pulse than with DSCT-Force (12.6 ± 2.7 % at 1.8 mGy, 9.1 ± 2.9 % at 6 mGy and 4.0 ± 2.7 % at 11 mGy). For all energy levels, f av values were significantly higher (p < 0.05) with DSCT-Pulse than with DSCT-Force at 1.8 mGy (4.8 ± 3.9 %) and at 6 mGy (5.5 ± 2.5 %) but similar at 11 mGy (0.2 ± 3.6 %; p = 0.518). For all energy levels, f 50 values were significantly higher with DSCT-Pulse than with DSCT-Force (12.7 ± 5.6 % at 1.8 mGy, 17.9 ± 4.5 % at 6 mGy and 13.1 ± 2.6 % at 11 mGy). For all keV, similar d' values were found with both DSCT-Force and DSCT-Pulse at 11 mGy (−1.0 ± 3.1 %; p = 0.084). For other dose levels, d' values were significantly lower with DSCT-Pulse than with DSCT-Force (9.1 ± 3.2 % at 1.8 mGy and −6.3 ± 3.9 % at 6 mGy). Conclusion Compared with the DSCT-Force, the DSCT-Pulse improved noise texture and spatial resolution, but noise magnitude was slightly higher and detectability slightly lower, particularly when the dose level was reduced.
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?