Rapid Surface Charge Mapping Based on a Liquid Crystal Microchip

Leixin Ouyang,Heyi Chen,Ruiting Xu,Rubia Shaik,Ge Zhang,Jiang Zhe
DOI: https://doi.org/10.3390/bios14040199
2024-04-19
Biosensors
Abstract:Rapid surface charge mapping of a solid surface remains a challenge. In this study, we present a novel microchip based on liquid crystals for assessing the surface charge distribution of a planar or soft surface. This chip enables rapid measurements of the local surface charge distribution of a charged surface. The chip consists of a micropillar array fabricated on a transparent indium tin oxide substrate, while the liquid crystal is used to fill in the gaps between the micropillar structures. When an object is placed on top of the chip, the local surface charge (or zeta potential) influences the orientation of the liquid crystal molecules, resulting in changes in the magnitude of transmitted light. By measuring the intensity of the transmitted light, the distribution of the surface charge can be accurately quantified. We calibrated the chip in a three-electrode configuration and demonstrated the validity of the chip for rapid surface charge mapping using a borosilicate glass slide. This chip offers noninvasive, rapid mapping of surface charges on charged surfaces, with no need for physical or chemical modifications, and has broad potential applications in biomedical research and advanced material design.
chemistry, analytical,nanoscience & nanotechnology,instruments & instrumentation
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to measure the charge distribution on solid surfaces quickly and non - invasively. Specifically, the author proposes a new method based on liquid - crystal microchips for evaluating the surface charge distribution on flat or soft surfaces. Traditional surface charge measurement methods face many challenges, such as: 1. **Electrophoresis method**: Combined with light - scattering or resistive - pulse sensing techniques, it can measure the surface charge of micro/nano - particles, but it cannot measure the charge on solid surfaces. 2. **Streaming potential method**: By applying a pressure gradient in the capillary channels made on the target surface to induce electrolyte flow, a streaming potential is generated. Although it is feasible in principle, the experimental setup is complex, and it can only measure the average bulk potential of the target surface and cannot perform charge - distribution mapping. 3. **Atomic force microscope (AFM)**: It can measure the surface charge distribution, but because it is difficult to control the distance between the probe and the surface and it needs to scan the entire surface point - by - point, it is slow and difficult to operate. 4. **Scanning ion - conductance microscope (SICM)**: It measures the surface charge density by the change in ion current caused when a single nanotube approaches a charged surface, but it also requires point - by - point scanning, which is time - consuming and complex to operate. 5. **Photoelectrochemical imaging systems (PEISs)**: It uses a focused laser beam to induce photocurrent on n - type semiconductor materials to measure the local charge on the cell surface. Although it has the ability to map surface charges, it still needs to scan the entire surface point - by - point and is relatively slow. To address these challenges, the author proposes a microchip method based on liquid crystals. The chip consists of an array of micropillars on a transparent indium - tin - oxide (ITO) substrate, and liquid crystals are filled in the gaps between the micropillar structures. When an object is placed on the chip, the local surface charge (or ζ - potential) will affect the orientation of liquid - crystal molecules, thereby changing the intensity of transmitted light. By measuring the intensity of transmitted light, the distribution of surface charge can be accurately quantified. This method enables non - invasive, real - time charge - distribution mapping of charged surfaces without the need for physical or chemical modification of the target surface, and has broad application prospects, especially in the fields of biomedical research and advanced material design.